Submit manuscript...
eISSN: 2377-4304

Obstetrics & Gynecology International Journal

Case Report Volume 10 Issue 3

Colpotomy in da vinci single-site hysterectomy: a case report and literature review 

Shadi Rezai,1 Alexander C Hughes,2 Mariam Chowdhari,2 Elise Bardawil,1 Cassandra E Henderson,3 Xiaoming Guan1

1Division of Minimally Invasive Gynecologic Surgery, Department of Obstetrics and Gynecology, Baylor College of Medicine, USA
2St. George’s University, School of Medicine, St. George’s, West Indies
3Maternal and Fetal Medicine, Department of Obstetrics and Gynecology, Lincoln Medical and Mental Health Center, USA

Correspondence: Xiaoming Guan MD PhD, Section Chief and Fellowship Director, Division of Minimally Invasive Gynecologic Surgery, Department of Obstetrics and Gynecology, Baylor College of Medicine, 6651 Main Street, 10th Floor, Houston, Texas, 77030, USA, Tel (832) 826-7464, Fax (832) 825-9349

Received: February 19, 2019 | Published: May 9, 2019

Citation: Rezai S, Hughes AC, Chowdhari M, et al. Colpotomy in da vinci single-site hysterectomy: a case report and literature review. Obstet Gynecol Int J. 2019;10(3):192-197. DOI: 10.15406/ogij.2019.10.00442

Download PDF

Abstract

Background: Vaginal cuff dehiscence (VCD) occurs after total hysterectomy with colpotomy when the surgical closure fails. Vaginal cuff dehiscence is defined as any separation of the edges of the cuff and vaginal evisceration is defined as the prolapse of intraperitoneal contents typically the small bowel. The rate of all vaginal cuff dehiscence (VCD) has been reported from 0.1% to 4.6% and with robotic assisted laparoscopy hysterectomies (RA-LH) as high as 7.5%. True estimated rates, however, of vaginal dehiscence are difficult to determine as most of the literature consists of case reports which have an inherent reporting bias. Vaginal dehiscence is rare compared to other surgical complications but due to its devastating nature warrants discussion.
Objective:The objective of this review was to compare a number of variables possibly associated with the VCD after total hysterectomy (TH). Variables compared were surgical hysterectomy approach (open, laparoscopic, vaginal and robotic), type of suture used to close the vaginal cuff (barbed or traditional), approach to colpotomy (open, laparoscopic, vaginal and robotic) and type of uterine manipulator used.
Case: A 50-year-old woman Gravida 0,Para 0, with a history of chronic pelvic pain and pelvic pressure, menorrhagia and anemia due to abnormal uterine bleeding secondary to leiomyoma (AUB-L) unresponsive to medical management therapy and symptoms affecting her daily activities presented to our clinic and requested laparoscopic hysterectomy. 
Patient underwent Da Vinci SILS TLH (robot-assisted total hysterectomy) with bilateral salpingectomy. Hysterectomy was modified by performing colpotomy prior to uterine artery cauterization and cardinal ligament transection.
Patient had uncomplicated hospital and recovery course and was discharged on postoperative day 1. Upon return to clinic on postoperative week 3 for postoperative followup, patient did not have any complaint and reported resolutions of symptoms.
Conclusion: The largest amount of evidence remains that the rate of VCD is associated with robotic and laparoscopic closure of colpotomy. Some authors have made local policy changes to improve care by only closing colpotomy vaginally and have met with success. Other institutions have begun using lower power during electrocautery in order to reduce tissue damage. Barbed sutures showing improved operative times and being well tolerated have been studied in the hopes of reducing VCD with one large study showing statistically significant results.

Keywords: barbed suture, closure technique, colpotomy, colpotomizer, cuff dehiscence, electrothermal injury, endoscopic suturing, hysterectomy, laparoscopic hysterectomy, minimally invasive hysterectomy, robotic surgery, thermal damage, thermal injury, total laparoscopic hysterectomy, transvaginal suturing, uterine manipulator, TLH, vaginal cuff dehiscence, vaginal cuff thermal injury, vault dehiscence, VCD

Background

Vaginal cuff dehiscence (VCD) occurs after total hysterectomy with colpotomy when the surgical closure fails. Vaginal cuff dehiscence is defined as any separation of the edges of the cuff and vaginal evisceration is defined as the prolapse of intraperitoneal contents typically the small bowel.1 The rate of all VCD has been reported from 0.1% to 4.6% and with robotic assisted laparoscopy hysterectomies (RA-LH) as high as 7.5%.2–5 True estimated rates, however, of VCD are difficult to determine as most of the literature consists of case reports which have an inherent reporting bias.4 Vaginal dehiscence is rare compared to other surgical complications but due to its devastating nature warrants discussion.6

Patients with VCD typically present with pelvic pain, pelvic mass and watery or bloody vaginal discharge.7 VCD is considered a surgical emergency and can occur anytime post operatively, most commonly occurring within approximately 7-13 weeks8 of surgery but cases have been reported after 1 year and up to 10 years post operatively.8

Risk factors unrelated to the surgical procedures include the risks associated with poor wound healing, multiple vaginal surgeries, vaginal atrophy and most commonly early postoperative coitus.4,7,9–12 When the indication for total hysterectomy (TH) includes malignancy the risk for VCD increases 3 fold.3,10 Surgical risk factors include hysterectomy approach, type of suture used to close the vaginal cuff and approach to colpotomy. Currently there is no standard for method of closure for colpotomy after TH.

Objective

The objective of this review was to compare a number of variables possibly associated with VCD after TH. Variables compared were surgical hysterectomy approach (open, laparoscopic, vaginal and robotic), type of suture used to close the vaginal cuff (barbed or traditional), approach to colpotomy (open, laparoscopic, vaginal and robotic) and type of uterine manipulator used.

Case

A 50-year-old woman Gravida 0, Para 0, with a history of chronic pelvic pain, pelvic pressure, menorrhagia and anemia due to abnormal uterine bleeding secondary to leiomyoma (AUB-L). Menses typically lasted for 2 weeks. She previously had uterine fibroid embolization (UFE) without much relief of symptoms. Her symptoms were affecting her daily living activities and were unresponsive to medical management. She presented to our clinic and requested laparoscopic hysterectomy.13

MRI of the pelvis showed an enlarged bulky leiomyomatous uterus 10.3×6.7×8.8cm in size with multiple fibroids including; subserosal fibroid -4.5cm×3.2cm, intracavitary/submucosal -4cm; Fundal intramural fibroid -5.2cm and an exophytic subserosal fibroid at the posterior uterine body -4.9×5.2×3.4cm

The patient underwent Da Vinci single incision laparoscopic hysterectomy (robotic-assisted total hysterectomy) with bilateral salpingectomy. The hysterectomy was modified by performing colpotomy prior to uterine artery cauterization and cardinal ligament transection (Figure 1) (Figure 2).

The patient had an uncomplicated hospital course and was discharged on postoperative day 1. Upon return to clinic on 3 weeks after surgery for postoperative follow up, the patient did not have any complaint and reported resolutions of symptoms.

Figure 1 Intraoperative picture showing colpotomy done prior to uterine artery ligation.

Figure 2 Intraoperative picture showing colpotomy done prior to uterine artery ligation.

Discussion

Some studies have shown that the majority of VCD occur within surgeons first 25 cases.14 We found that by performing the colpotomy before uterine artery cauterization and cardinal ligament transection helped build up junior surgeon’s confidence and reduce surgical complications.13

Comparison of type of dissection used (sharp vesrus thermal)

Dissection during TH may be performed with or without the use of thermal energy. It has been proposed that tissue damage during electrocautery dissection of the colpotomy may contribute to poor wound healing and decrease tissue integrity.15 Hur et al.,16 found the incidence of VCD laparoscopic hysterectomies (using thermal dissection) to be higher than vaginal hysterectomies (using sharp dissection) and postulated this was due to thermal damage.16 Supporting this hypothesis are animal models showing impaired wound healing when comparing sharp dissection to electrocautery17,18 and histological examination of human tissue after electrocautery showed signs of chronic inflammation which could indicate delayed wound healing.19 Subsequently the energy settings of electrocautery have been examined and the rate of vaginal cuff complications were generally lower with ‘cut’ rather than ‘coag’ settings.20,17 In order to reduce energy damage some have suggested suturing for hemostasis rather than using electrocautery.11 Rotithor and Hur have suggested methods for no energy dissection during endoscopic surgery in order to reduce the incidence of VCD, but to date no definitive results have been reported.16,21

Studies have been published with conflicting results regarding the effect of thermal injury on the rate of VCD.3,22,23 Comparative reports where both arms used electrocautery but different approaches, remained to show a difference indicating energy effects were less likely to be a factor in the rate of VCD.5,23 Additionally, Weizman et al.3 found neither the source or the level of energy effected the rate of VCD.3 No conclusive study has yet to be performed and some authors believe thermal energy is not a significant factor in the rate of VCD.3,23,24

Comparison of approach to colpotomy closure

With development of minimally invasive surgery techniques and robotic technology allowing for ‘elbowed’ instruments, laparoscopic suturing has become easier but remains an advanced surgical skill and takes many hours to master.25 Many surgeons are choosing to perform hysterectomies with either laparoscopic or robotic techniques as they have shown superior patient outcomes especially with regards to faster surgical times, improved pain control, reduced blood loss and reduced hospital stay.26,27 Robotic systems have shown to decrease overall surgical time but colpotomy closure remains the most time consuming step in hysterectomies.25 Unfortunately, several studies agreed the rate of VCD is significantly higher when using robotic or laparoscopic surgery specifically when closing the colpotomy.4,23,28–30 Some studies have found the increase in VCD rate is specific to robotic systems.5

As discussed above thermal energy damage has been thought to contribute to the increased rate of VCD as it is the most common mode of dissection during endoscopic procedures. It has also been proposed that the magnification of the 3D camera when using robotic systems could lead the surgeon to place the stitch closer to the incisional boarder not incorporating enough healthy tissue contributing to VCD.2,11,31 Conversely, the vaginal approach to closure allows for greater tissue purchase and superior knot tying during colpotomy closure.31 No studies have been performed to date which test this hypothesis comparing measured tissue bites in robotic closure of colpotomy.

With growing evidence suggesting VCD is associated with laparoscopic and robotic closure of vaginal cuff, Ucella, proposed vaginal closure regardless of surgical approach should become the gold standard for hysterectomies but to date no coconscious has been reached.3,23,29,31 Stevens and Ucella have both made this their standard and observationally report success in their institutions after converting all TH to vaginal cuff closure.29,31

Comparison of type of uterine manipulator used (Hohl vs VCare®)

Uterine manipulators are commonly used to assist in hysterectomies. They were developed to assist in colpotomy with advent of a cup which can surround the cervix providing a surface for dissection and manipulating the uterus to prevent injury.32,33 However, many models exist with different designs, and no single model has clearly shown any benefit during TH. 

Some of the most commonly used uterine manipulators on the market today are the Hohl manipulator and VCare® manipulator both of which use a cervical cup. Although the benefits of different uterine manipulators may depend on surgeon preference, the rate of VCD associated with each does not significantly vary. 

In a product review for VCare® manipulator, Greenberg found the main advantage during TH was it reduced surgical times and reduced the rate of injury to the ureters or bladder.34 Akdemir and Cirpan discussed how although the Hohl manipulators were easy to use and decreased the rate of VCD, complications arose mainly from improper use of the manipulator.35 Such complications were uterine perforation and bowel injury, they concluded that improper use of manipulator may overshadow it’s advantages.35 

Van den Haak et al.36 highlighted the use of uterine manipulators for prevention of ureter injuries during TH, however there is still lack of data regarding how this prevention occurs.36 Ultimately, Van den Haak concluded use of uterine manipulators in TH is unlikely to negatively impact the outcome of TH, but was inconclusive in the direct benefit on the rate of VCD.36         

Comparison of type of suture used to close colpotomy

Laparoscopic suturing is an advanced surgical skill and is often the most time consuming portion of TH.25 Barbed sutures were developed to in order to keep wound edges approximated and maintain tension during closure allowing for easier running suturing. The development of barbed sutures has improved the learning curve for endoscopic suturing27,28,37–39 and sustained tension provided while suturing the approximated edges leads to greater tissue stability. Unfortunately, because the rate of VCD is very low many studies when adopting barbed sutures examined how they were tolerated by patients postoperatively and showed no increase in common postoperative complications such as infection, pain or postoperative bleeding.27,39

The most recent notable report of barbed sutures on the effect of VCD was published in 2015 by Rettenmaier et al.40 in which they compared the use of barbed sutures with Vicryl sutures in endoscopic (laparoscopic and robotic surgery) hysterectomies.40 With a sample size of 1876 they were able to see a statistically significant reduction in VCD.40 In fact no VCD were found to occur when barbed sutures were used.40,41 These findings are similar to other observational studies with much smaller sample sizes.13,39

Conclusion

In conclusion through a thorough literature review of VCD there are obviously numerous factors which contribute to the risk of VCD (Table 1). A major risk factor as many authors agree is the precipitating event of early coitus illustrating the importance of patient teaching and emphasizing following recommendations. Those risks which are within the power of the physician to control should be modified in order to reduce the risk of VCD. The largest amount of evidence remains that the rate of VCD is associated with robotic and laparoscopic closure of colpotomy. Some authors have made local policy changes to improve care by only closing colpotomy vaginally and have met with success. Other institutions have begun using lower power during electrocautery in order to reduce tissue damage. Barbed sutures showing improved operative times and being well tolerated have been studied in the hopes of reducing VCD with one large study showing statistically significant results.

 

Author

Year

Type

# Pts

Results

1.

Kashani2

2012

Observational case series

654

0.4% VCD with RAH

2.

Weizman3

2015

Retrospective

2,382

0.96% VCD rate overall

0.50% VCD with TAH

0.32% VCD with TVH

1.05% VCD with TLH

3.15% VCD with TRH

3.

Ceccaroni7

2011

Multicentric Retrospective

8635

0.39% VCD

4.

Hur9

2011

Observational cohort study

12,472

1.35% VCD with TLH

5.

Drudi10

2013

Prospective Descriptive

441

1.6% VCD with RAH

All oncology cases

6.

O'Hanlan11

2016

Retrospective Cohort Study

1924

0.26% VCD

7.

Hada12

2010

Retrospective

677

0.6% VCD with TLH

8.

Dauterive14

2012

Retrospective chart review

731

2.61% VCD with RALH

1.94% with TLH

(P = 0.60)

9.

Lawlor20

2015

Retrospective

150

0.2% VCD

10.

Fanning23

2013

Prospective analysis

610

0% VCD with LAVH

4% VCD with TLH

(P = 0.02)

11.

Nick24

2011

Retrospective study

417

1.7% VCD overall

1.1% VCD with TLH

3.0% VCD with TRH

(P = 0.22)

12.

Kim26

2014

Retrospective

604

0.49% evisceration,

3.47% VCD with

13.

Blikkendaal28

2012

Retrospective Cohort Study

331

1.3% VCD with transvaginal interrupted sutures

3.3% VCD with laparoscopic interrupted sutures

2.4% VCD with laparoscopic running sutures

14.

Uccella30

2012

Multi-institutional analysis

12,398

0.64% VCD with TLH

0.21% VCD with TAH

0.13% VCD with TVH

15.

Koo42

2013

Retrospective study

9,973

0.6% VCD with AH

0.4% VCD with TLH

Not statistically significant

16. 

Lopez43

2016

Retrospective Cohort Study

100

2% VCD

17.

Kho44

2009

Retrospective

510

4.1% VCD with RAH

18.

Shin45

2011

Retrospective

168

No VCD reported with TLH and LAVH

19. 

Chen46

2017

Retrospective

585

0.3% VCD with RAH

Table 1 Mode of Hysterectomy and percentage of vaginal cuff dehiscence (VCD)

Acknowledgments

Dr. Xiaoming Guan is a speaker for Applied Medical, Rancho Santa Margarita, California.

Conflicts of interest

Other authors did not report any potential conflicts of interests.

References

  1. Matthews CA, Kenton K. Treatment of vaginal cuff evisceration. Obstet Gynecol. 2014;124(4):705–708.
  2. Kashani S, Gallo T, Sargent A, et al. Vaginal cuff dehiscence in robotic-assisted total hysterectomy. JSLS. 2012;16(4):530–536.
  3. Weizman NF, Einarsson JI, Wang KC, et al. Vaginal cuff dehiscence: risk factors and associated morbidities. JSLS. 2015;19(2):e2013.00351.
  4. Cronin B, Sung VW, Matteson KA. Vaginal cuff dehiscence: risk factors and management. Am J Obstet Gynecol. 2012;206(4):284–288.
  5. Uccella S, Ghezzi F, Mariani A, et al. Vaginal cuff closure after minimally invasive hysterectomy: our experience and systematic review of the literature. Am J Obstet Gynecol. 2011;205(2):119.e1–12.
  6. Aydogmus H, Aydoğmuş S, Gençdal S, et al. Cuff closure by vaginal route in TLH: case series and review of literature. J Clin Diagn Res. 2017;11(3):QD01–QD03.
  7. Ceccaroni M, Berretta R, Malzoni M, et al. Vaginal cuff dehiscence after hysterectomy: a multicenter retrospective study. Eur J Obstet Gynecol Reprod Biol. 2011;158(2):308–313.
  8. Kumar S, Singhal S, Kansal Y, et al. Recurrent vaginal cuff dehiscence in a treated case of carcinoma cervix. J Clin Diagn Res. 2017;11(9):QD01–QD02.
  9. Hur HC, Donnellan N, Mansuria S, et al. Vaginal cuff dehiscence after different modes of hysterectomy. Obstet Gynecol. 2011;118(4):794–801.
  10. Drudi L, Press JZ, Lau S, et al. Vaginal vault dehiscence after robotic hysterectomy for gynecologic cancers: search for risk factors and literature review. Int J Gynecol Cancer. 2013;23(5):943–950.
  11. O'Hanlan KA, Emeney PL, Peters A, et al. Analysis of a standardized technique for laparoscopic cuff closure following 1924 total laparoscopic hysterectomies. Minim Invasive Surg. 2016;2016:1372685.
  12. Hada T, Andou M, Kanao H, et al. Vaginal cuff dehiscence after total laparoscopic hysterectomy: examination on 677 cases. Asian J Endosc Surg. 2011;4(1):20–25.
  13. Neubauer NL, Schink PJ, Pant A, et al. A comparison of 2 methods of vaginal cuff closure during robotic hysterectomy. Int J Gynaecol Obstet. 2013;120(1):99–101.
  14. Dauterive E, Morris G 4th. Incidence and characteristics of vaginal cuff dehiscence in robotic-assisted and traditional total laparoscopic hysterectomy. J Robot Surg. 2012;6(2):149–154.
  15. Rappaport WD, Hunter GC, Allen R, et al. Effect of electrocautery on wound healing in midline laparotomy incisions. Am J Surg. 1990;160(6):618–620.
  16. Hur HC, Guido RS, Mansuria SM, et al. Incidence and patient characteristics of vaginal cuff dehiscence after different modes of hysterectomies. J Minim Invasive Gynecol. 2007;14(3):311–317.
  17. Iwanoff CJ, Barbier HM, Massengill JC, et al. Laparoscopic colpotomy using monopolar electrocautery: does power really matter? Female Pelvic Med Reconstr Surg. 2015;21(3):141–145.
  18. Gruber DD, Warner WB, Lombardini ED, et al. Laparoscopic hysterectomy using various energy sources in swine: a histopathologic assessment. Am J Obstet Gynecol. 2011;205(5):494.e1–6.
  19. Klauschie J, Wen Y, Chen B, et al. Histologic characteristics of vaginal cuff tissue from patients with vaginal cuff dehiscence. J Minim Invasive Gynecol. 2014;21(3):442–446.
  20. Lawlor ML, Rao R, Manahan KJ, et al. Electrosurgical settings and vaginal cuff complications. JSLS. 2015;19(4):e2015.00088.
  21. Rotithor PR. Colpotomy in total laparoscopic hysterectomy without using an energy source: a new approach. Proceedings in Obstetrics and Gynecology. 2014;4(3):8.
  22. Teoh D, Lowery WJ, Jiang X, et al. Vaginal cuff thermal injury by mode of colpotomy at total laparoscopic hysterectomy: a randomized clinical trial. J Minim Invasive Gynecol. 2015;22(2):227–233.
  23. Fanning J, Kesterson J, Davies M, et al. Effects of electrosurgery and vaginal closure technique on postoperative vaginal cuff dehiscence. JSLS. 2013;17(3):414–417.
  24. Nick AM, Lange J, Frumovitz M, et al. Rate of vaginal cuff separation following laparoscopic or robotic hysterectomy. Gynecol Oncol. 2011;120(1):47–51.
  25. Torres D, Lang TG, Pasic R, et al. Identifying the rate-limiting step in total laparoscopic hysterectomy in a training hospital. J Minim Invasive Gynecol. 2015;22(6):974–979.
  26. Kim MJ, Kim S, Bae HS, et al. Evaluation of risk factors of vaginal cuff dehiscence after hysterectomy. Obstet Gynecol Sci. 2014;57(2):136–143.
  27. Nawfal AK, Eisenstein D, Theoharis E, et al. Vaginal cuff closure during robotic-assisted total laparoscopic hysterectomy: comparing vicryl to barbed sutures. JSLS. 2012;16(4):525–529.
  28. Blikkendaal MD, Twijnstra AR, Pacquee SC, et al. Vaginal cuff dehiscence in laparoscopic hysterectomy: influence of various suturing methods of the vaginal vault. Gynecol Surg. 2012;9(4):393–400.
  29. Uccella S, Ghezzi F. Effects of electrosurgery and vaginal closure technique on postoperative vaginal cuff dehiscence. JSLS. 2015;19(1):e2015.003594.
  30. Uccella S, Ceccaroni M, Cromi A, et al. Vaginal cuff dehiscence in a series of 12,398 hysterectomies: effect of different types of colpotomy and vaginal closure. Obstet Gynecol. 2012;120(3):516–523.
  31. Stevens A, Parsa MA, Paka C, et al. Vaginal cuff dehiscence in a series of 12,398 hysterectomies: effect of different types of colpotomy and vaginal closure. Obstet Gynecol. 2013;121(1):189–190.
  32. Jackson T, Advincula AP. Optimization strategies for colpotomizer technology during total laparoscopic hysterectomy. Surg Technol Int. 2012;22:183–188.
  33. Singh SJ. Total laparoscopic hysterectomy: using an active colpotomizer enhances ureteric safety. J Minim Invasive Gynecol. 2011;18(6):S33.
  34. Greenberg JA. VCare® uterine manipulator/elevator, winter 2009 product reviews. Rev Obstet Gynecol. 2009;2(1):69–70.
  35. Akdemir A, Cirpan T. Iatrogenic uterine perforation and bowel penetration using a Hohl manipulator: A case report. Int J Surg Case Rep. 2014;5(5):271–273.
  36. Van den Haak L, Alleblas C, Nieboer TE, et al. Efficacy and safety of uterine manipulators in laparoscopic surgery: a review. Arch Gynecol Obstet. 2015;292(5):1003–1011.
  37. Bogliolo S, Musacchi V, Dominoni M, et al. Barbed suture in minimally invasive hysterectomy: a systematic review and meta-analysis, Arch Gynecol Obstet. 2015;292(3):489–497.
  38. Ardovino M, Castaldi MA, Fraternali F, et al. Bidirectional barbed suture in total laparoscopic hysterectomy and lymph node dissection for endometrial cancer: technical evaluation and 1-year follow-up of 61 patients. J Laparoendosc Adv Surg Tech A. 2013;23(4):347–350.
  39. Kim JH, Byun SW, Song JY, et al. Barbed versus conventional 2-layer continuous running sutures for laparoscopic vaginal cuff closure. Medicine (Baltimore). 2016;95(39):e4981.
  40. Rettenmaier MA, Abaid LN, Brown JV 3rd, et al. Dramatically reduced incidence of vaginal cuff dehiscence in gynecologic patients undergoing endoscopic closure with barbed sutures: A retrospective cohort study. Int J Surg. 2015;19:27–30.
  41. Huang F, Gisseman J, Guan X. Colpotomy: a novel visible landmark for laparoscopic hysterectomy education, video session 6 - Basic science/research/education, video number 321. J Minim Invasive Gynecol. 2016; 23(7):S124.
  42. Koo YJ, Kim DY, Kim JH, et al. Vaginal cuff dehiscence after hysterectomy. Int J Gynaecol Obstet. 2013;122(3):248–252.
  43. Lopez S, Mulla ZD, Hernandez L, et al. A comparison of outcomes between robotic-assisted, single-site laparoscopy versus laparoendoscopic single site for benign hysterectomy. J Minim Invasive Gynecol. 2016;23(1):84–88.
  44. Kho RM, Akl MN, Cornella JL, et al. Incidence and characteristics of patients with vaginal cuff dehiscence after robotic procedures. Obstet Gynecol. 2009;114(2 Pt 1):231–235.
  45. Shin JW, Lee HH, Lee SP, et al. Total laparoscopic hysterectomy and laparoscopy-assisted vaginal hysterectomy. JSLS. 2011;15(2):218–221.
  46. Chen CH, Chen HH, Liu WM. Complication reports for robotic surgery using three arms by a single surgeon at a single institution. J Minim Access Surg. 2017;13(1):22–28.
Creative Commons Attribution License