Assessment of activity concentration and effective doses from bioassay sample of occupational workers in NINMAS, Bangladesh

Jannatul Ferdous,1 Sagar Hossain,2 Begum F,3 MD Ashraful Hoque1

1Heath physics Division, Bangladesh
2Department of Physics, Dhaka University, Bangladesh
3National Institute of Nuclear Medicine and Allied sciences, Bangladesh

Correspondence: Jannatul Ferdous, Heath physics Division, Atomic Energy Center, Dhaka, Bangladesh, Tel 8801716275050

Received: September 21, 2016 | Published: December 20, 2016

Citation: Ferdous J, Hossain S, Begum F, et al. Assessment of activity concentration and effective doses from bioassay sample of occupational workers in NINMAS, Bangladesh. Int J Radiol Radiat Ther. 2016;1(2):33-36. DOI: 10.15406/ijrrt.2016.01.00008

Download PDF

Abstract

This aim of this study is to estimate the activity concentration and committed effective doses from Bioassay sample such as urine samples of Nuclear Medicine workers due to intake of 131I and 99mTc. For internal radiation monitoring, 37 urine samples are collected from occupational workers of National Institute of Nuclear Medicine and Allied Science (NINMAS) in Bangladesh. These urine samples have been analyzed using High Purity Germanium (HPGe) detector. The radioactivity of 131I and 99mTc were found 5.78±0.861 BqL-1 to 389.95±30.01 BqL-1 and 24.47±2.14 BqL-1 to 1529.5±36.05 BqL-1 respectively. The effective doses of occupational workers have been also calculated using the radioactivity concentration and the dose coefficients which were given in ICRP publication 78. For manipulating the unsealed source of 99mTc, the highest and lowest effective doses were 48.8 and 1.15µSv respectively, for handling 560 and 120 mCi of 99mTc radionuclide. On the other hand, the highest and lowest effective doses were 6.82 and 0.158µSv respectively, for handling 2000 and 100mCi of 131I radionuclide. These values are within limits, however to avoid inhalation and contamination of 131I and 99mTc proper working environment should be established with suitable ventilation system, fume hood, mask, etc.

Keywords: radioactivity, effective dose, bioassay sample, occupational worker, nuclear medicine and allied science

Abbreviations

HPGe, high purity germanium; MCA, multichannel analyzer

Introduction

Unsealed radioactive sources such as 131I and 99mTc are used in Nuclear Medicine Centers, to diagnose and treat patients, pose significant risks of internal exposure to the occupational workers. 131I is highly volatile and radiotoxic, which may pose an occupational radiological hazard, especially in places where significant activities are routinely handled. In such situations, worker handling unsealed sources of 131I may be internally exposed by inhalation. Though 99mTc is not as volatile, however it is the most widely used imaging agents in nuclear medicine. Moreover, due to short half life the internal radiation risk that it poses may sometimes be over looked. Although it is recognized that in nuclear medicine centers external exposure is usually higher than internal exposure, the risks associated with intakes should be estimated in each case and, if necessary, staff involved in the handling of unsealed sources should be routinely monitored in order to ensure that individual doses are kept as low as possible.1 Internal monitoring should also be performed in response to an accident or suspected inhalation or ingestion intake. 131I is a short-lived radionuclide (half-life; 8days). It decays by beta emission producing photons of 0.36MeV. For adults, it is assumed that, of the iodine reaching the blood, 30% is transported to the thyroid gland and other 70% is excreted directly in urine via the urinary bladder. The biological half-life in blood is taken to be 6h. Iodine incorporated into thyroid hormones leaves the gland with biological half-life of 12days. Most iodine (80%) is subsequently released and is available in the circulation for uptake by the thyroid or direct urinary excretion; the remainder is excreted via the large intestine in the faeces. Because of the short physical half-life of 131I, this recycling is not important in terms of the committed effective dose. Iodine is rapidly absorbed into the circulation following inhalation or ingestion. It is concentrated in the thyroid and excreted predominantly via urine.2 There are 17 Nuclear Medicine Centers in Bangladesh, from these Centers only one is selected for this study: National Institute of Nuclear Medicine and Allied Science (NINMAS) Dhaka. While processing and labeling of the liquid sources with labeling compounds, the sources may enter the bodies of the occupational worker through inhalation and ingestion. The present work was taken up to measure the contamination of the occupational staff because of the above radiopharmaceuticals.

Materials and methods

Collection and preparation of samples

Workers were advised to read collecting instructions provided together with the pots. The main concern in this methodology was to reduce the possibility of external contamination of the pots. 37 urine samples of 17 occupational workers were collected after 3 to 4 hours of handling of 131I and 99mTc from the National Institute of Nuclear Medicine and Allied Science (NINMAS), Dhaka. These samples were kept in standard plastic pots previously identified with name, date and time of collection and activity of handling isotope. Samples were processed immediately after collection and measured with the HPGe detector system coupled to a Multichannel Analyzer (MCA) at the Health Physics Division, Atomic Energy Centre, and Dhaka under the Bangladesh Atomic Energy Commission. The volumes of the urine samples were measured and were found to be less than 350ml. Finally, the samples were taken in plastic bags and positioned in the HPGe detector to perform the measurement. Due to several reasons such as non availability of radioactive sources, working conditions, etc., it was not possible to collect urine sample periodically.

Radioactivity measurement

After completion of necessary quality assurance of the HPGe detector the radioactivity of the samples were measured. The liquid nitrogen dewar of the HPGe detector was filled with liquid nitrogen at least 12hours before the measurement. This allowed sufficient time for cooling of the detector. The detector system was turned on and a 15minute warm-up period was allowed before the first measurement of each day. The high voltage bias supply to the detector was gradually raised to the operating voltage (+1600 Volt.), the amplifier coarse gain, fine gain and peak shaping time were also adjusted to the desired values.3 After all these settings had been done, a period of about half an hour was allowed for stabilization of the system. Then the energy calibration of the detector was checked by placing 137Cs and 60Co point sources at the detector axis with a source-to-detector distance at about 10 cm for 100 seconds, so that 661.66keV, 1170keV, and 1332keV peaks could appear in the appropriate channels. Then a background spectrum was obtained by placing an empty plastic container on the top of the well-shielded detector head for 5000seconds. After taking the background reading, each of the sample-filled plastic containers was placed on top of the detector head and then the entrance door to the shielding arrangement was closed. The sample’s counts were acquired for 5000 seconds. The computer software “Mestro-32” was used to transform the data of each sample. The analysis sheet contained the energy of emitted gamma photons and the corresponding counts per second including the statistical error. After searching for the particular radionuclide’s peak and taking the corresponding counts per sec, the total activity for the particular sample was calculated by the following equation,

A= Net cps p γ .e.w MathType@MTEF@5@5@+= feaagKart1ev2aqatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeaeaaaaaa aaa8qacaWGbbGaeyypa0tcfa4aaSGaaOWdaeaajugib8qacaWGobGa amyzaiaadshacaGGGcGaam4yaiaadchacaWGZbaak8aabaqcLbsape GaamiCaKqba+aadaWgaaWcbaqcLbsapeGaeq4SdCgal8aabeaajugi b8qacaGGUaGaamyzaiaac6cacaWG3baaaaaa@492D@ (1)

Where A=activity of the radionuclide present in the samples in units of Bq l-1, cps=counts per sec, pγ=the fraction of a particular gamma-ray energy, e=efficiency of the detector for a particular gamma-ray energy (emitted from the specific radionuclide of interest), w=Quantity (volume) of the sample in liters.

The mean background reading from a set of measurements was subtracted from each of the sample
reading. Every time before carrying an experiment, a number of operations of HPGe detector had to
be done, such as

    1. Energy calibration,
    2. Energy resolution,
    3. Efficiency calibration and
    4. Estimation of lower limit of detection for each of the detecting radionuclides. During the read out period, the Dewar flask was filled by liquid nitrogen.

Evaluation of committed effective dose

The concentration of 131I and 99mTc radionuclides in the urine samples of the nuclear medicine staff, which were measured with HPGe semiconductor detector, were converted into the concentration per daily urinary volume from which the daily intake and the committed effective dose were evaluated using the following equation.4

H A = I Aj h Aj MathType@MTEF@5@5@+= feaagKart1ev2aqatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamisaK qbaoaaBaaabaqcLbmacaWGbbaajuaGbeaajugibiabg2da9iabggHi LlaadMealmaaBaaajuaGbaqcLbmacaWGbbGaamOAaaqcfayabaqcLb sacaWGObWcdaWgaaqcfayaaKqzadGaamyqaiaadQgaaKqbagqaaaaa @4852@ (2)

Where HA is the committed effective dose or the committed equivalent dose (Sv) by inhalation for adult, hAj is the inhalation dose coefficient (Sv/Bq) for the effective dose or for the target organ considered for the radionuclide j.5

For an acute intake at time t before the measurement, the activity of the radionuclide inhaled can be calculated by

I Aj = E j / e aAj ( t ) MathType@MTEF@5@5@+= feaagKart1ev2aqatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamysaK qbaoaaBaaabaqcLbmacaWGbbGaamOAaaqcfayabaqcLbsacqGH9aqp caWGfbWcdaWgaaadbaGaamOAaaqabaqcLbsacaGGVaGaamyzaSWaaS baaWqaaiaadggacaWGbbGaamOAaaqabaqcfa4aaeWaaOqaaKqzGeGa amiDaaGccaGLOaGaayzkaaaaaa@47A1@ (3)

Where IAj is the activity (in Bq) of the radionuclide j inhaled by a member of adult; Ej is the whole body activity of the radionuclide j or the activity of the radionuclide j in the organ considered, obtained by direct measurement (in Bq); eaAj (t) is the fractional activity in total body or in the organ considered at time t after an acute inhalation ‘a’ of the radionuclide j by a member of age group adult. Values of eaAj (t) have been calculated using the biokinetic models and data described in ICRP Publication 78.

Results and discussion

Activity concentration of 131I & 99mTc

As it is seen in the Table 1 & 2, the concentration of 131I radionuclide was observed in 14 samples, whereas presence of 99mTc was detected in 14 samples. No radioactivity was observed in the rest of the 9 samples because in those samples the radioactivity concentration is in minimum detection level.

No. of occupational worker

Activity±error in BqL-1 131I (364.48 kev)

Effective dose (μSv) for 131I

1

86.67±3.069

1.71

2

58.86±2.476

1.16

3

155.22±5.350

3.05

4

5.78±0.861

0.114

5

9.79±1.654

0.193

6

8.02±1.080

0.158

7

161.8±6.264

3.18

8

MDL

0

9

MDL

0

10

MDL

0

11

9.22±0.16

0.181

12

MDL

0

13

33.15±2.40

0.652

14

MDL

0

15

MDL

0

16

346.41±7.407

6.82

17

260.85±5.694

5.13

18

59.53±2.87

1.17

19

389.95±11

7.67

20

12.46±1.545

0.245

Table 1 Measurement of activity concentration and effective doses of occupational workers for 131I

No. of occupational worker

Activity±error in BqL-1 99mTc (140.47Kev)

Effective dose (μSv) for 99mTc

21

41.13±2.772

1.93

22

66.49±0.003

3.12

23

107.49±4.48

5.04

24

31.48±2.48

1.47

25

MDL

0

26

1040.7±19.3

48.8

27

MDL

0

28

1102.73±26.3

51.7

29

670.25±21.41

31.4

30

24.47±2.14

1.15

31

123.38±10.73

5.78

32

MDL

0

33

144.52±7.89

6.77

34

51.37±4.68

2.41

35

50.81±3.092

2.38

36

1529.5±36.05

71.7

37

243.83±12.19

11.4

Table 2 Measurement of activity concentration and effective doses of occupational workers for 99mTc

 The concentration ranges of 131I was from 5.78±0.861 BqL-1 to 389.95±11 BqL-1 and the concentration ranges of 99mTc was from 24.47±2.14 BqL-1 to 1529.5±36.05 BqL-1. The highest and lowest detected radioactivity concentrations of 131I in urine samples were 389.95±11 BqL-1 and 5.78±0.861 BqL-1 respectively, whereas the highest and the lowest detected radioactivity concentrations of 99mTc in urine samples were 1529.5±36.05 BqL-1 and 24.47±2.14 BqL-1 respectively. There was no radioactivity concentration of 99mTc in the urine samples of female workers but the concentrations of 131I was found in the urine samples of the female workers. The highest and lowest concentrations of 131I in female workers were 389.95±11 BqL-1 and 8.02±1.080Bq/L. On the other hand the radioactivity concentrations of both 99mTc and 131I were found in urine samples of the male workers. For male workers the highest detected radioactivity concentrations of 99mTc and 131I were 1529.5±36.05 BqL-1 and 260.85±5.694 BqL-1 respectively, whereas the lowest detected radioactivity concentrations were 24.47±2.14 BqL-1 and 5.78±0.861 BqL-1 respectively.

It was inferred that the worker with 131I concentration in urine might inhale 131I radionuclide which was diffused into the air because of its volatile nature, during the distribution job of 131I. The possible reason for 99mTc concentration in urine is for unconscious manipulation in the workplace. Even though the radiation contamination by occupational worker is low in Bangladesh, continued vigilance should be maintained to minimize this concentration as much as possible.

Measurement of effective dose

The effective dose of 131I and 99mTc in urine samples of occupational staff were calculated using equations (2) and (3). The result of committed effective dose of 99mTc and 131I in urine samples of occupational staff is also given in Table 1 & 2.

Due to manipulate the unsealed source of 131I, the highest and lowest effective doses were 7.67µSv and 0.114µSv respectively, for handling 2000mCi and 100mCi of 131I radionuclide. On the other hand the highest and lowest effective doses 71.70µSv and 1.15µSv respectively, for handling 560mCi and 120mCi of 99mTc radionuclide.

The effective doses of occupational workers due to inhalation and contamination of 131I and 99mTc radionuclides were found low in comparison with annual effective dose of an occupational worker which is 20µSv. The results of concentrations and doses can contribute to improve through regulations and deciding the radiological policies for the internal dosimetry of the radiation staff handling the radioisotopes in the medical fields.

Conclusion

The experimental results showed that the procedures on internal monitoring are very useful for controlling of radiation workers working with unsealed radioactive sources, in particular, in the case of inhalation of 131I and contamination of 99mTc. The results of activity concentration due to intake of 131I and 99mTc can contribute to improve the regulations and deciding the radiological policies for internal dosimetry of radiation workers handling the radioisotopes in the nuclear medicine fields. The result also shows that the nuclear medicine occupational workers in Bangladesh are not in risk of radiation hazards. Even though the 131I concentration in urine of nuclear medicine staff in Bangladesh is low, the occupational staff in nuclear medicine practices of Bangladesh should try to keep this concentration as low as possible. Proper working environment should be established such as suitable ventalation system, fume hood, musk, to avoid inhalation and contamination of 131I and 99mTc respectively. Finally, this study can be expanded to a basic one for guaranteeing the reliability for the results of internal doses for handling of 131I and 99mTc.