Mini Review Volume 5 Issue 6
1Centre for Nano Science and Engineering, Indian Institute of Science, India
2Department of Engineering Physics, University of Wisconsin, USA
3Department of Materials Engineering, Indian Institute of Science, India
4Nanotechnology and Water Sustainability Unit, University of South Africa, South Africa
Correspondence: Manoj M Varma, Centre for Nano Science and Engineering, Indian Institute of Science, Bangalore-560012, India
Received: June 14, 2017 | Published: August 1, 2017
Citation: Pahal S, Gakhar R, Raichur AM, Varma MM (2017) Probing Bio-Molecules across Polyelectrolyte Multilayers. J Nanomed Res 5(6): 00140. DOI: 10.15406/jnmr.2017.05.00140
Highly tuneable architecture of PEMs with nanometres precision is the most promising aspect to utilize them for variety of applications. The bulk loading properties of polyelectrolyte multilayer thin films (PEM) motivate researchers to utilize them as a carrier for biomedical applications. For designing an efficient carrier polymeric assembly for targeted and controlled drug delivery, it is very important to understand the loading and release kinetics of bio-molecules across PEM matrix. Therefore, a better and complete understanding of the molecular diffusion is highly recommended to achieve success in these areas. This mini review provides an overview of the current efforts in understanding the bio-molecular transport across the polymer thin films. Different strategies involving confocal-based approaches along with recent innovative techniques have been briefly explained here to probe biomolecules in PEM. Pros and cons of each technique with future perspectives are discussed to render the most suitable technique for understanding the permeability of desired polymer matrix.
Keywords:polyelectrolyte multilayer films, bioactive,fluorescence, microscopes
Polyelectrolyte multilayer films (PEM) are the most potential candidate for drug delivery applications as they offer stimuli sensitive and well-tuned bulk architecture with nanometres precision for loading of drug or bioactive species.1˗4 For an efficient loading and targeted release of bio-active molecules, it is very important to understand the availability of encapsulated drug or bio-molecules within the polymer matrix.5,6 This local availability of the incorporated molecules is dependent on the transport properties of the particular PEM stack and is usually measured by the displacement of the adsorbed molecule in a given time scale with respect to its initial position or from the interface of loading. For tracking bio-molecules or probing bio-molecular location across PEM matrix, it is important to apply the best technique without compromising the PEM's structural integrity. So far, researchers have explored a variety of techniques to estimate bio-molecular transport with varying degree of success. The main aim of this mini review is to provide an overview of the present research focused on understanding the bio-molecular transport in polymer thin films. Such an effort will lead to the design of better host materials for drug loading and various other bioactive species for the advancement of multi-component, targeted and controlled drug delivery applications.
Optical techniques such as confocal microscopy are based on fluorescence from the diffusing species. The salient features of confocal microscopes over the conventional fluorescence microscopes, such as better resolution and improved contrast, render it suitable to study molecular dynamics in biological samples. Moreover, confocal microscopy also provides three dimensional transport information in case of thicker samples by offering the optical sectioning and image reconstruction options. In order to acquire accurate, time-resolved information of molecular transport and to understand details of molecular interactions, a number of technical modifications have been implemented in the conventional confocal systems. Fluorescence Recovery after Photobleaching (FRAP), Forster Resonance Energy Transfer (FRET) and Fluorescence Correlation Spectroscopy (FCS) are the examples of such modified versions of conventional confocal microscopes. Table 1 discusses the detailed overview of the techniques mentioned in this review.
Technique |
Bio-Molecule |
PEM Stack |
Pros and Cons |
Confocal-Based Techniques |
|||
FRAP (Fluorescence Recovery |
Protein Lysozyme (Lys), |
poly(L lysine) |
-Best for studying lateral |
FRET |
Chitosan (CH) |
Chitosan/heparin |
-Useful for biomolecule probing |
FCS |
Rhodamine B (RB) |
poly(sodium |
Reveals Fast molecular dynamics |
Recent Innovative Techniques |
|||
Depth-profile X-ray |
Chitosan (CHI) |
poly(ethylene oxide) |
-Can determine interlayer diffusion |
Modified SERS Surface-enhanced |
Methylene Blue ( MB) |
poly(allylamine |
-Minimize diffusion and long |
VERTICAL Diffusion |
Bovine Serum Albumin (BSA) & Biotin |
poly(allylamine hydrochloride) |
Probe vertical transport in |
Table 1 Provides an overview of the recent research activities which are focused on probing the bio-molecular transport across PEM
Fluorescence recovery after photo bleaching is the most versatile optical technique confocal microscopy for studying molecular transport within the biological cells. FRAP relies on the photo-induced bleaching of a region of interest (ROI) by utilizing a high intensity laser and monitoring the change in fluorescence intensity with time scale in order to track the molecular diffusion from the area surrounding bleached ROI.7 The recovery or the change in the fluorescence intensity of the ROI contains the information about the diffusion of molecules, which are labelled with fluorophores and diffusion coefficients can be extracted by fitting this data to various mathematical models. Existing literature contains a number of examples where FRAP has been employed to study bio-molecular transport in PEMs.8˗11 In fact, FRAP is the most used technique for studying the lateral molecular transport across PEM.9,10 Very recently, FRAP has been utilized to study the interaction and loading behaviour of Lysozyme protein and Human Serum Albumin (HSA) across the polymeric stack of Poly(L-lysine) (PLL) and hyaluronic acid (HA).8,9 Due to the exponential layer growth in this system, this PEM stack is thick enough to be explored for excellent loading (Table 1).
FRAP has proved to be a versatile tool here, as it helps in studying the protein dynamics across PEM with different PEM compositions and varying physico-chemical surroundings, such as the terminating polymer layer, the deposition concentration, temperature, ionic strength and pH of the PEM constituents. In order to better understand the bio-interactions, FRAP is also used to detect differences in the diffusion behaviour of different proteins with varying molecular sizes within the same PEM stack.11 A major limitation of FRAP is that it can only be employed to explore molecular transport in PEM films with thickness more than a micron because of limited Z-resolution of confocal microscopy.
To investigate out-of-plane transport in thin polyelectrolyte multilayers, other optical techniques such as the Fluorescence Resonance Energy Transfer (FRET) and Fluorescence Correlation Spectroscopy (FCS) are better alternatives.12˗16 For example, out-of-plane transport of chitosan (CH) has been observed in films of CH and heparin (HEP) by using FRET.12 Here, CH molecules were labelled by either a donor dye or an acceptor dye. Donor-acceptor energy transfer is extremely sensitive to the distance between the fluorophores and therefore serves as a reporter of changes in the proximity of labelled polymers as they diffuse. These FRET experiments indicated that CH molecules diffused within the film with a transport coefficient that was not significantly sensitive to the deposition pH and solution ionic strength. Thus by utilizing FRET, polymer dynamics can be monitored in the vertical direction with significantly improved spatial resolution compared to FRAP.
Fluorescence Correlation Spectroscopy is also among the optical technique, which provides valuable information on the diffusive polymeric exchange in solution surrounding PEM stack.14˗16 FCS is also known as Single Molecule Confocal Microscopy as it is very sensitive to very small molecular interactions within the PEM. The lateral transport of Rhodamine B (RB) was studied in the PEM films of sodium poly(sodium 4-styrenesulfonate)(PSS) and poly (diallydimethlyammonium chloride) (PDDA) by FCS.16 FCS is able to provide information about molecular transport across the PEM stack at different temporal scales of several sub-microseconds to several hundred milliseconds. All the confocal-based techniques require the fluorescent modification of molecules being tracked and give indirect measurements of transport characteristics of PEMs.
Depth-profile XPS
Techniques such as X-ray photoelectron spectroscopy (XPS) with depth-profile option have proven to be capable of probing transport in inorganic materials.17 However, the use of such techniques for studying transport in soft polymeric thin films suffers from several challenges. XPS can damage either the polymer layers or change the structural organization of bioactive species under investigation. Therefore, in order to generate error-proof data, specialized conditions are required for using XPS for probing bio-molecular transport. For example, C60+ cluster ions have recently been used for generating high resolution depth-profiling XPS analysis to minimize the damage to soft materials. Here, efficacy of hydrogen bonding is compared with electrostatic interactions for blocking interlayer transport of Chitosan (CHI) across multilayer stack of poly (ethylene oxide)/poly (acrylic acid (PEO/PAA). By using this high resolution depth-profile XPS, it has been verified that (CHI) can diffuse easily into the hydrogen-bonded region i.e. (PEO/PAA), where as a single layer of poly(allylamine hydrochloride) PAH, which is an electrostatic blocking-layer, is sufficient in stopping the CHI diffusion into the PEM stack. Such a design of PEM stack, with interlayer blocking capability is proposed to be highly beneficial for sustained drug release applications.
Modified SERS
Recently, molecular transport has been studied by utilizing specially designed Surface-enhanced Raman spectroscopy (SERS) substrates.18 Here, the SERS substrates have been modified with polyelectrolyte multilayers of poly (allylamine hydrochloride) (PAH) and poly (acrylic acid (PAA) by layer-by-layer (LbL) process. Wrapping these SERS probes with PEM has proven to be efficient for their long term storage by reducing the transport of reporter molecules into the surrounding environment. To study this effect, methylene blue was used as an optical reporter molecule, which was encapsulated with the PEM stack. SERS signals were recorded from these Raman active reporters over a period of 5 weeks. To minimize transport and improve the long-term storage stability of these nanoprobes, thiol coating and cross-linking strategies were used. In both cases, molecular transport is significantly diminished. Such a method of polyelectrolyte wrapping on SERS substrates is an easy way to protect them from harsh biological environment for long observation period.
This is one of the most recent optical techniques for extracting bio-molecular transport across PEM in transverse direction (normal to the substrate). This technique offers the ability to study transport in ultrathin polymer films (thickness 100-200nm).19 This technique is based on the distance-dependent periodic modulation of fluorescence intensity emitted from the fluorescently labelled molecule. Thus, diffusion profile can be extracted by measuring the fluorescence emission from the different polymer thickness. This technique has been employed to study the transport of bovine serum albumin (BSA) and biotin across the polymeric stack of poly (allylamine hydrochloride) PAH/ poly (acrylic acid) PAA. The experimental demonstrations were in agreement with a proposed mathematical model which was validated by probing molecular transport in the PEM under different environmental conditions to either enhance or suppress the molecular diffusion across polymer films. This technique also provides a clear picture of molecular loading into the PEM.
As PEM serves as the most effective stimuli-sensitive reservoir platform for various bio-medical applications, so it is essential to gain insights into the loading and releasing of biomolecules across the multilayer stack. Most of the research in this field is mainly focussed on understanding the physico-chemical aspects of PEM. This minireview provide a good overview of current research for tracking the location and availability of bio-molecules across the PEM stack, which is essential for variety of applications ranging from biomedical applications to other surface coatings, designing effective membrane separations etc. Confocal-based techniques that involve the fluorescently tagged diffusing molecules and some recent innovations in this field have been discussed in this paper. This knowledge opens new facets of bio-molecular interactions within PEM. Such monitoring or tracking of molecules is essential for creating desired carrier architectures for drug delivery applications where on-time, on-demand availability of bio-molecules is crucial. Overall, this effort will greatly expand the knowledge about the dynamical aspects of biomolecular transport occurring in PEM stack and provides new possibilities for designing the novel class of carrier materials for better therapeutic applications.
We do not have any acknowledgment for the study.
All authors have no conflicts of interest to declare.
None.
©2017 Pahal, et al. This is an open access article distributed under the terms of the, which permits unrestricted use, distribution, and build upon your work non-commercially.