Submit manuscript...
Journal of
eISSN: 2376-0060

Lung, Pulmonary & Respiratory Research

Proceeding Volume 2 Issue 1

What characterizes patients who are CPAP adherent?

Sorensen J

PRO2 Respiratory Services, Lexington, USA

Correspondence: Sorensen J, PRO2 Respiratory Services, Lexington, KY, USA, Tel ÿ8599403355

Received: December 12, 2014 | Published: January 23, 2015

Citation: Sorensen J. What characterizes patients who are CPAP adherent? J Lung Pulm Respir Res. 2015;2(1):24. DOI: 10.15406/jlprr.2015.02.00031

Download PDF

Introduction

We assessed the factors associated with CPAP use in a clinical setting.

Methods

We retrospectively reviewed clinical data for patients who had CPAP provided by a single Home Medical Equipment company. Respiratory therapists made phone call follow-ups at 24/48hours and 7/10days to address problems. Data was collected from surveys and from computer cards inserted in CPAP machines at 30days, 60days, and 6 months.

Results

In this unselected group of 109 consecutive patients (57% men, 40% smokers), 64% had verified average use of >4hours of use per night and average use was 6hours at 6months. The 3most common benefits reported by patients were improved sleep quality (62%), fewer trips to the bathroom at night (49%), and more alert driving (39%). Adherence was no different for those who had in-laboratory titrations (n=23) compared with those who were empirically treated with auto-titrating CPAP (n=83). Interventions at follow-up included change in mask type or fit (34%), pressure change (44%), and mode change (10%). Overall, 34, 37 and 29% chose full face, nasal pillows, or nasal masks respectively; at 6months, use of >4hrs/night by mask type was 72%, 43%, and 50% respectively. Twenty one percent (23/109) discontinued CPAP treatment within the first 2months, including 11 smokers, and 17 with AHI´s <30/hr. Seven of these patients undertook alternative treatment with surgery (4), oral appliances (1), or weight loss (2); 3 switched to oxygen, bi-level pressure, or auto-titrating CPAP. Eleven remain untreated.

Conclusion

CPAP adherence in clinical practice may be better than what is classically reported. Involvement of an RT may improve adherence. Changes in mask type and pressure are frequent. In discussing benefits of CPAP with patients, improved sleep, reduced nocturia and better driving performance should be emphasized.

Acknowledgements

None.

Conflict of interest

The author declares no conflict of interest.

Creative Commons Attribution License

©2015 Sorensen. This is an open access article distributed under the terms of the, which permits unrestricted use, distribution, and build upon your work non-commercially.

Citations