Background: Dental imaging is a helpful aid in the diagnosis of maxillofacial lesions. The dentists have to access benefits against its hazards and be aware of different radiation protection techniques. 

Objectives: To assess knowledge, approach and perceptions (KAP) of undergraduate Saudi dental students towards biological hazards of dental x-ray and appropriate radiographic protection techniques. To compare KAP between preclinical and clinical undergraduate students.

Materials and Methods: The study participants included 57 dental undergraduate students (preclinical and clinical years), whose curriculum includes x-ray physics. The information was collected via an online 21 structured multiple choices questionnaires. Statistical analysis: Mann–Whitney U tests at a 5% significance level were used to analyze the difference between the different answers of the 2 groups tested. 

Results: Among 57 samples enrolled in the study 42 were in preclinical and 15 were in clinical dental years. Over all correct response was ranged from 22%-76% in the preclinical group & from 33.3%-72.7 in the clinical group. A clear consensus was noticed among the 2 groups evaluated for all questions with insignificant differences between all answers of the survey. 

Conclusion: The Knowledge, approach and perception (KAP) level regard to biological hazards effect of x- ray was noted to be low to medium in both groups. Concern the different protection protocols the KAP was found to be ranged from medium to high general knowledge also in the 2 groups. This outcome necessitates continual teaching to ensure maximum safety.

Keywords: knowledge; approach; radiography; protection; hazards; dentists

Introduction

It is well known that ionizing radiation has biological damaging effects, either affecting the cell directly or indirectly via the production of free radicals. Both lead to DNA damage, including single or double-strand breaks, and or DNA protein cross-links.1 Biological hazards are classified based on occurrence probability into: Non-stochastic and stochastic effect. Non stochastic or deterministic, in which there is determined dose above which the damaging insults start to appear. Stochastic effect, meaning that there is no deterministic dose that could lead to biological damage. High-dose ionizing radiation (x-ray) has both deterministic and stochastic effects. In contrary to lower doses, radiation hazards are primarily stochastic rather than deterministic.2−4

The International Commission on Radiological Protection (ICRP) began to develop the risk/benefit concept since 1977. This concept recommended that all patient exposures must be justified and kept as low as possible.5 So it is a mandatory issue to follow the ALARA principle “As Low as Reasonably Achievable” during dentist routine work.6 However, ALARA principles are not strictly applied in the dental field.7,8 Both dentist and patients are at high risk of stochastic effects as it has no dose threshold. The benefit of disease detection should be weighed against the risk of biological hazards of x- ray.9 Additionally, the amount of radiation exposure from dental radiographs depends on many variables starting from film speed, going through exposure factors, selected technique, collimation and protecting barriers used. The clinical year dental students and interns (junior residential doctors/ house surgeons) should have thorough knowledge towards the biological hazards of x- ray and different protection protocols.10 In spite of the biological hazards of x- ray, enormous benefits were derived from its application in the medical and dental fields. Furthermore, dental imaging produces least radiation dose if compared to medical imaging.11

Undergraduate students will be future dentist who will be at risk of radiation biological hazards during their life. They should be aware of different protection methods against x- ray. The dentist should be aware of different radiation protective methods as well as the daily received radiation dosage. The aim of the present study was to assess knowledge, approach and perceptions (KAP) of biological hazards of dental x- ray and appropriate radiographic protection among Saudi dental students, moreover to compare KAP between preclinical and clinical undergraduate students.

Materials and methods

The present study was confirmed by an ethical research committee of Taibah University of dental school. A cross sectional study was performed on 57 undergraduate students (preclinical and clinical) of Saudi Arabia dental schools. KAP assessment was gathered by questionnaire following Prabhat et al.10 with slight modification.

The questionnaire related to biological hazards of dental radiographs and radiation protocol in the form of multiple choices was given to each participant through an online monkey survey. The questions of the questionnaire were divided into three categories.

  1. The first group of questions was to classify the samples to undergraduates, interns & postgraduates, moreover to classify the gender of the samples and to be sure that all the included samples had studied oral radiology course.
  2. A second group of questions were to assess the KAP towards the biological hazards of x- ray. This part contained 5 questions:
    1. Is dental X-ray harmful?
    2. Do X-ray beams reflect from room walls?
    3. Do X- ray cause Ionization to matter? 
    4. Are you aware of deterministic effects and stochastic effects?
    5. Is dental radiograph absolutely contraindicated in pregnant patients?
  3. The third category of questions was to assess the KAP regarding the radiographic protection guidelines. This part was enclosed of 8 questions:
    1. Are you aware of ALARA principle?
    2. Are you aware of National Council on Radiation Protection (NCRP) and International Commission on Radiological Protection (ICRP) recommendations? 
    3. Are you aware of usefulness of collimators and filters in dental radiography?
    4. Does digital radiography require less exposure than conventional?
    5. Does the high speed film require a reduced exposure?
    6. Do you prefer to hold the films during exposure?
    7. What is the ideal distance an operator should stand while taking intraoral radiographic exposure?
    8. Do you use lead aprons on a regular basis?

Statistical analysis

Mann–Whitney U tests at a 5% significance level were used to analyze the difference between the different answers of the 2 groups tested where group 1 was 1st to 3rd year student and group 2 were 4th to 6th year students.

Statistical analysis was performed with IBM® SPSS® (SPSS Inc., IBM Corporation, NY, USA) Statistics Version 21 for Windows.

Ethical consideration

This study was approved by the Research Ethical Committee of Taibah University; a waiver of informed consent was accepted as all the study subjects were unknown.

Results

Responders

Among 66 samples only 57 samples were enrolled in the present study as 9 samples were excluded from the survey as they did not complete Oral Radiology course. The samples included 42 preclinical students and 15 students in clinical dental years, 61.4% of participants were females (Table 1).

 Sex

Group

Total

Preclinical Group 2nd-3rd Years

Clinical Group 4th-6th Years

Count

Column N (%)

Count

Column N (%)

Male

14

34.1

8

50.0

22

Female

27

65.9

8

50.0

35

Total

41

16

57

Table 1 Classification of the participants based on grouping

KAP results

As regards the biological hazards KAP of dental imaging, the overall correct response ranged from 22%-76% in the preclinical group and from 33.3%-72.7 in the clinical group (Figures 1−4). A clear consensus was noticed among the 2 groups evaluated for all questions without statistical significance different between all answers of the survey (Table 2).

Figure 1 From the column chart 67.3% students know that dental X-rays were harmful, 46.3% know that for X-rays cannot be reflected from the walls of the room & 54.1% of the students know that Dental radiographs were not absolutely contraindicated to pregnant patients. The pie chart showed that 30.2% only who were aware of deterministic effects and stochastic effects.
Figure 2 From the column chart only 24.5 % students knew NCRP and ICRP. Figure 1, showed 75.7% of the responders prefer not to hold dental film by their finger& 54.8% were always preferred using lead aprons.
Figure 3 The pie chart shows the knowledge of the dental students toward different protection methods. A 71.7%, 40.5% of the dental students were aware of the usefulness of collimators and filters in dental radiography, ALARA principle respectively. Moreover, 64.9% were known that digital radiography requires less exposure than conventional and that high speed films reduce exposure respectively.
Figure 4 The pie chart shows that 65.6% of the students understand the importance of wearing the personal monitoring badges. Only 46.7% of the students were know the ideal position of the operator during intraoral dental exposure.

No.

 

Group

p-value

Preclinical Group
2nd- 3rd Years

Clinical Group
4th -6th Years

Count

%

Count

%

1

Is dental X-ray harmful?

Yes

22

52.4

10

66.7

0.505 NS

No

17

40.5

3

20.0

Don't Know

3

7.1

2

13.3

2

Do X-ray beams reflect from room walls?

Yes

11

26.2

5

33.3

0.922 NS

No

21

50.0

5

33.3

Don't Know

10

23.8

5

33.3

3

Are you aware of National council on radiation protection [NCRP] and International commission on radiological Protection [ICRP] recommendations?

Yes

9

21.4

3

20.0

0.483 NS

No

19

45.2

5

33.3

Don't Know

14

33.3

7

46.7

4

Are you aware of the usefulness of collimators and filters in dental radiography?

Yes

27

64.3

11

73.3

0.571 NS

No

5

11.9

1

6.7

Don't Know

10

23.8

3

20.0

5

Are you aware of deterministic and stochastic effects?

Yes

11

26.2

5

33.3

0.325 NS

No

16

38.1

7

46.7

Don't Know

15

35.7

3

20.0

6

Are you aware of ALARA principle?

Yes

9

21.4

6

40.0

0.261 NS

No

8

19.0

2

13.3

Don't Know

25

59.5

7

46.7

7

Does digital radiography require less exposure than conventional?

Yes

17

40.5

6

40.0

0.967 NS

No

2

4.8

1

6.7%

Don't Know

23

54.8

8

53.3

8

Does the high speed film require a reduced exposure?

Yes

17

40.5

7

46.7

0.626 NS

No

5

11.9

2

13.3

Don't Know

20

47.6

6

40.0

9

Do you prefer to hold the films during exposure?

Yes

3

7.1

1

6.7

0.919 NS

No

20

47.6

7

46.7

Don't Know

19

45.2

7

46.7

10

Do you ask the patient to hold the film with their hand during exposure?

Yes

13

31.0

3

20.0

0.884 NS

No

10

23.8

6

40.0

Don't Know

19

45.2

6

40.0

11

Does dental radiograph absolutely contraindicated in pregnant patients?

Yes

11

26.2

3

20.0

0.655 NS

No

11

26.2

7

46.7

Don't Know

20

47.6

5

33.3

12

Should personal monitoring badges be worn by the operator?

Yes

15

35.7

6

40.0

0.708 NS

No

2

4.8

1

6.7

Don't Know

25

59.5

8

53.3

13

Will you adhere to the radiation protection protocol in the future?

Yes

17

40.5

8

53.3

0.388 NS

No

3

7.1

1

6.7

Don't Know

22

52.4

6

40.0

14

What is the ideal distance an operator should stand while taking intraoral radiographic exposure?

4 feet and 90°-135°

1

2.4

1

6.7

0.782 NS

4 feet and 60°-90°

8

19.0

0

0.0

6 feet and 90°-135°

12

28.6

8

53.3

6 feet and 60°-90°

4

9.5

2

13.3

Don't Know

17

40.5

4

26.7

15

Do you use lead aprons on a regular basis?

Always

17

40.5

5

33.3

0.737 NS

Often

4

9.5

4

26.7

Sometimes

3

7.1

2

13.3

Rarely

0

0.0

0

0.0

Never

1

2.4

0

0.0

Don't Know

17

40.5

4

26.7

16

If never/rarely/ sometimes, why not?

No availability of apron

1

2.4

3

20.0

0.089 NS

Due to weight of the apron

2

4.8

2

13.3

Common apron for all

0

0.0

0

0.0

I follow only position rule

1

2.4

0

0.0

I follow only distance rule

2

4.8

1

6.7

Don't know

36

85.7

9

60.0

Table 2 Table showing the questions given to the participant and their response group

Discussion

Several years ago many studies were directed for the measurement of radiation exposure and had shown the increased occurrence of cancer, abortion, fetus mutagenic changes, cataracts and shortening of life span. Although the previous statement being non-definite and non-applicable for diagnostic dental radiography, it is still acceptable to apply stochastic biological hazards effect.12

Stochastic effects are those effects which follow the probability of occurrence of biological hazard effects, dose independent compared to deterministic effects (i.e. the patient may either shows biological damaging effect or not affected at all, with a minimal radiation exposure). Therefore, the radiation protection protocol should focus on prevention of the deterministic effects occurrence and to reduce the probability of stochastic effects, that is why dentists should be restricted to the “As Low As Reasonably Achievable” ALARA principle concept 6,12,13.

In order to achieve these goals, a thorough knowledge about the biological hazards of x- ray, is a must, in order to do proper radiation protection protocols.

Considering this, in the present study, Undergraduate students (both preclinical and clinical years of bachelor of dental surgery) were selected.

The study showed that among all the groups, a KAP difference to the basic physics and biological damaging effect of x- ray was noted.

Although the results of the present study showed that 52.4% of preclinical group and 66.7% of the clinical group consider x- ray to be harmful, relatively it is still to a low percentage that make them keen in taking precautions against this harm.

A classic question that is usually asked by patients and the technician through your daily work, do X-ray beams reflect from room walls?, 50.0 % of the 1st group and 33.3% of the 2nd group answered NO. This result is dreadful if you think that the entire participant will be one day future dentist who will use dental radiographs in a regular basis.

The results of the present study showed that 42.3% of the 1st group and 27.3% of the 2nd group considering that it is absolutely contraindicated to take dental radiographs for a pregnant female. To simplify this result, about 30- 50 % of the future dentist will dismiss the pregnant women from their clinic, regardless their pregnancy semester, the level of emergency and regardless the different precautions measurement that should be done for these deprived women. In support of our study a previous study was done on 250 general dentists, the author's concluded that the studied population of dentists does not seem to have the sufficient knowledge regarding the diagnostic dental radiation risk during pregnancy.14

When the participants were questioned about their awareness of deterministic and stochastic effect: 26.2% of the 1st group and 33.3% of the 2nd group were yes. This means that about 70% of them were unaware of the probability of occurrence of radiation biological damage, either by under or over estimation of radiation biological hazard effects.

In the present study, 68.0%-72.7% participants claimed that they will adhere to radiation protection protocol in their future clinical practice. From the results of the present study, it is debatable that the future dentists were aware of the radiation protection protocols. In support of our results,10 evaluated undergraduate dental students and interns in their study, their results showed that among 234 samples enrolled in the study, 172 were undergraduates (80 from third year and 92 from the fourth year). The overall correct response was 77.3% and it was noted in descending order from Interns (90.62%), followed by fourth year (83.8%) and third year students (61%).10

Conclusion

From the response obtained through our study, it is obvious that the KAP level of the biological hazards effect of x- ray was low to medium in both groups. The radiation protection principle is to take certain precautions that will minimize exposure to dental professional and patients together with gaining benefits for the patients. Although the level of KAP of the different protection protocols of the both groups was found to be ranged from medium to high general knowledge also in the 2 groups, this outcome necessitates continual teaching to ensure maximum safety. So, it is preferable to do a refresh program at regular intervals at institutional and national level for strict adherence of different radiographic protection regulation protocols.

Acknowledgements

None.

Conflict of interest

The authors have no declared potential conflicts of financial interest, relationships and or affiliations relevant to the subject matter or materials discussed in the manuscript.

References

  1. Ribeiro DA, de Oliveira G, de Castro G, et al. Cytogenetic biomonitoring in patients exposed to dental X-rays: comparison between adults and children. Dent Omaxillofac Radiol. 2008;37(7):404−407.
  2. Little MP, Wakeford R, Tawn EJ, et al. Risks associated with low doses and low dose rates of ionizing radiation: why linearity may be (almost) the best we can do. Radiology. 2009;251(1):6−12.
  3. S. National Academy of Sciences, National Research Council. Committee to Assess Health Risks from Exposure to Low Levels of Ionizing Radiation. Health Risks from Exposure to Low Levels of Ionizing Radiation. BEIR VII Phase 2. The National Academies Press, Washington, DC; 2006.
  4. United Nations Scientific Committee on the Effects of Atomic Radiation. UNSCEAR 2006 Report to the General Assembly, with scientific annexes. Effects of Ionizing Radiation. Volume I Report to the General Assembly, Scientific Annexes A and B. New York, United Nations. 2008.
  5. Recommendations of the ICRP. ICRP Publication 26. Ann ICRP. 1977;1(3).
  6. White SG, Pharoah MJ. Oral radiology: principles and interpretation. Mosby, St. Louis, USA;2004:25−46.
  7. Kantor ML. Longitudinal trends in the use of individualized radiographic examinations at dental schools in the United States and Canada. J Dent Educ. 2006;70(2):160−168.
  8. Lee B-D, Ludlow JB. Attitude of the Korean dentists towards radiation safety and selection criteria. Imaging Sci Dent. 2013;43(3):179−184.
  9. Haring JI, Lind LJ. Chapter 5: Radiation protection in Textbook of Dental Radiography Principles and Techniques. W.B. Saunders. Company;1996”64−79.
  10. Prabhat MPV, Sudhakar S, Kumar BP, et al. Knowledge, attitude and perception (KAP) of dental undergraduates and interns on radiographic protection- A questionnaire based cross-sectional study. Journal of Advanced Oral Research. 2011;2(3).
  11. American Dental Association Council on Scientific Affairs. The use of cone-beam computed tomography in dentistry. An advisory statement from the American Dental Association Council on Scientific Affairs. J Am Dent Assoc. 2012;143(8):899−902.
  12. Karjodkar FR. Chapter 6: Protection from radiation in Textbook of Dental and Maxillofacial Radiology, First edition. Jaypee Brothers Medical Publishers, New Delhi, India,49-65.
  13. World Health Organization. Efficacy and radiation safety in interventional radiology. Chapter 2: Radiation safety, A.I.T.B.S. Publishers & Distributors, Delhi, India;2002:26−55.
  14. Razi T, Bazvand L, Ghojazadeh M. Diagnostic dental radiation risk during pregnancy: awareness among general dentists in Tabriz. J Dent Res Dent Clin Dent Prospects. 2011;5(2):67−70.
Creative Commons Attribution License