Submit manuscript...
Journal of
eISSN: 2572-8466

Applied Biotechnology & Bioengineering

Research Article Volume 1 Issue 1

Development of bone particulate reinforced epoxy composite for biomedical application

Oladele IO, Isola BA

Department of Metallurgical and Materials Engineering, Federal University of Technology, Akure, Nigeria

Correspondence: Oladele IO, Department of Metallurgical and Materials Engineering, Federal University of Technology, Akure, Nigeria

Received: September 07, 2016 | Published: October 25, 2016

Citation: Oladele IO, Isola BA. Development of bone particulate reinforced epoxy composite for biomedical application. J Appl Biotechnol Bioeng. 2016;1(1):35-40. DOI: 10.15406/jabb.2016.01.00006

Download PDF

Abstract

Mechanical properties of particulate goat bone reinforced epoxy composite were investigated in this research. This was aimed at assessing the suitability of the developed composites for biomedical applications. The combination of the two materials for the development of the composites was targeted to meet good surface compatibility in addition to the structural compatibility needed as biomaterials. The composites were developed by compounding the matrix and the reinforcement in predetermined proportions and were fabricated by open mould technique. Mechanical properties such as tensile, flexural and hardness properties as well as wear behaviour were tested. From the results, XRF analysis showed that the main elements present in the goat bone ash are calcium and phosphorus with 71.6 and 16.6% contents, respectively. It was observed that improved mechanical properties were obtained for higher wt. percent reinforced composites from 16-20wt. percent compared to lower wt. percent composites from 2-14wt. percent. Bone particulate reinforced epoxy composite developed from 16wt. percent gave the best tensile and flexural properties and also possesses good and favourable hardness properties. However, improved wear resistance was observed at low wt. percent fraction of the reinforcement within 2-6wt. percent. Examination of the fractured surfaces by Scanning Electron Microscopy showed that the particulates were well dispersed within the matrix and the reason for the enhancement in the properties. Sample with optimum performance was 16 wt. percent bone particulate reinforced epoxy composite which has the best combination of mechanical and wear properties. The combination of good properties obtained made the developed composite to be suitable for biomedical application and, therefore, selected as the best composite material for biomedical application having met the structural conditions necessary.

Keywords: composites, biomaterial, epoxy, goat bone, mechanical properties, wear property

Introduction

A progressive deterioration of all tissues with age is the major contributor to the need for spare parts for the body. Bone tissue is susceptible to fracture as a result of trauma, pathology and resorption.1 This effect is especially severe in women due to the hormonal changes associated with menopause. Bone density decreases because bone-growing cells become progressively less productive in making new bone and repairing micro-fractures. The lower density greatly deteriorates the strength of bones and an unfortunate consequence is that many old people fracture their hips or have collapsed vertebrae and spinal problems.2

Bone fixation and repair devices traditionally are fabricated with metals and used clinically.3 Stainless steel, titanium and its alloys have been employed for the majority of fracture fixation treatments.4 However these metallic devices and implants are not biodegradable and often require a second surgery in order to remove these from the body. This not only increases the hospitalization time and health care cost but also elevates chances of infection and complications. Also, due to the mismatch between the mechanical properties of these devices and the natural bone, mechanical forces and loads are retained by implants and are not transferred to the healing bone which results in unwanted bone resorption and implant loosening.5

Metals are known for high strength, ductility and resistance to wear, however, the shortcomings of many metals includes; low biocompatibility, corrosion, too high stiffness compared to tissues, high density and release of metal ions which may cause allergic tissue reactions. Ceramics are known for their good biocompatibility, corrosion resistance and high compression resistance, nevertheless, the drawbacks of ceramics include; brittleness, low fracture strength, difficult to fabricate, low mechanical reliability, lack of resilience and high density. The above said complexities give way for the next generation bone implants that are polymeric based which have better biocompatibility. One of the substitute material based that are gaining attention is the utilization of abundantly available natural materials as reinforcement materials in polymer matrix composite. Goat bone being a natural material from animal source is expected to have good surface compatibility in addition to the structural compatibility needed as biomaterials. Composite is a material comprised of two or more metal, polymer or ceramic structures which are separated by an interface. Composite materials have been widely used for a long time in innovative technological applications due to their superior mechanical properties.6

Many matrix and reinforcement components of composite materials have been tried by several researchers in tissue engineering to advance the mechanical features, biological functions and to deliver special molecules. Biocompatible polymers have been mostly applied as matrix for composite materials associated with ceramic fillers in tissue engineering. Although ceramics are generally stiff and brittle materials, polymers are known to be flexible and exhibit low mechanical strength and stiffness. Composites aim to combine the properties of both materials for medical applications.7

The interest in natural fiber-reinforced polymer composite materials is rapidly growing both in terms of their industrial applications and fundamental research. They are renewable, cheap, completely or partially recyclable and biodegradable. Their availability, renewability, low density and price as well as satisfactory mechanical properties make them an attractive ecological alternative to glass, carbon and man -made fibers used for the manufacturing of composites.8

Biomaterials are materials of natural or man-made origin that are used to direct, supplement, or replace the functions of living tissues of the human body.9 They involve complete or part of a living organism or biomedical device which performs, augments or replace any natural function.10 Nowadays, biomaterials are commonly used in various medical devices and systems; synthetic skin; drug delivery systems; tissue cultures; hybrid organs; synthetic blood vessels; artificial hearts; cardiac pacemakers; screws, plates, wires and pins for bone treatments; total artificial joint implants; skull reconstruction; dental and maxillofacial applications.

Researchers have begun to focus attention on natural fiber composites (i.e., bio composites) which are composed of natural or synthetic resins reinforced with natural fibers.11 Investigated the influence of cow bone particle size distribution on the mechanical properties of polyester matrix composites in order to consider the suitability of the materials as biomaterials. It was discovered that fine cow bone particles lead to improved strength while coarse particles lead to improved toughness. The results also showed that these materials are structurally compatible and since they are developed from animal fiber based particle, it is expected to also aid the compatibility with the surface conditions as biomaterials. Park et al.12 studied the effects of particulate cow bone additions on the mechanical properties and tribological behavior of cow bone reinforced polyethylene composite in order to assess the possibility of using it as a new material for engineering applications. The results revealed that tensile strength and the hardness values of the composite increased with increase in wt. percent of the cow bone particles while the impact strength and rigidity decreased. The study also revealed that the additions of the particulate cow bone have the most significant main effect on the wear behavior of the composite while the interactions between load and time has no significant effect. Hence, bone particles could be used to improve the strength and wear properties of recycled low density polyethylene (RLDPE).

A lot of research has been done on natural fiber reinforced polymer composites but researches on goat bone based polymer composites have not been exploited. Against this background, the present research was undertaken with an objective to explore the potential of goat bone polymer composites as biomedical materials.

Materials and methods

Materials

The main materials for the investigation are goat bone which serves as the particulate reinforcement phase and Epoxy resin and hardener which serves as the matrix phase.

Method

Preparation of goat bone particulate: The goat bone was scraped to remove meat remnants, washed thoroughly to remove any oil and then sun dried for 2 weeks. The goat bone were calcined in the furnace at 400 ºC for 4 hours to eliminate any protein present and then cooled in air. The calcined bone was reduced to smaller sizes with the use of hammer prior to pulverizing in the ball mill. The bone were pulverized into finer particles with a ball mill followed by sieving using the sieve shaker to obtain the required grain size of 75μm undersize particulate.

Composites production: The composite was produced using the open mould technique.13 A mixing ratio of 2:1 (epoxy: hardener) was selected based on the epoxy-hardener manufacturer’s instruction. Bone particulate was varied in a predetermined proportion of 2, 4, 6, 8, 10, 12, 14, 16, 18 and 20 wt. %. The three moulds used for the fabrication were for tensile, flexural and wear specifications. The samples were left to cure in the mould for four hours after which it is removed and dried in air for 28 days before testing.

Mechanical test: Three tests were performed for each composite composition to guarantee reliability of the data generated from the average values that were used as the representative values.14

Tensile test: Tensile test was carried out in accordance to American Standard Testing and Measurement Method D412 (ASTM D412 1983) on Instron Universal testing machine. The tests were carried out using the displacement control at a rate of 5 mm/min. Composite samples with 3 mm thick and of gauge length 150 mm were used. Three identical samples were tested for each weight fraction from where the average values were used as the representative values.

Flexural test: Three point bend tests were performed in accordance to ASTM D 790 M to measure flexural properties using Instron Universal testing machine.15 The tests were carried out using the displacement control at a rate of 10 mm/min. The samples were of 150 x 50 x 3 mm. Three samples were tested for each weight fraction used and the average values were taken to represent the actual values.

Hardness test: Rockwell hardness test was conducted on the specimen using a standard Rockwell hardness tester, Indentec, AK4150. The sample were mounted on the hardness tester support and then indented with a load of about 60 Kgf for 10 seconds. The hardness value was displayed on the digital surface of the machine that shows the readings. Each sample was indented in three places and the average value was used as the representative values.

Wear test: The wear resistance test was carried out with Taber Abrasers, Model ISE–AO16. The standard load used was 500 g and revolution of 150 RPM, center hole of 10 mm was made on the sample, so as to fix the test piece on the machine. The samples were measured using an analytical weighing balance to take the initial weight of the samples. The sample was secured to the instrument platform, which is a motor driven at a fixed speed. Thereafter, the weight was measured as the final value and the difference between the initial and the final value was noted and recorded against each samples. The average values were used as the representative value.16

X-ray Fluorescence spectroscopy (XRF): X-ray fluorescence was also carried out on the bone particles to determine the elemental chemical composition of the goat bone particulate. SKYRAY Instrument was used with EDX3600B X-Ray fluorescence spectrometer been applied to conduct fast and accurate analysis. The instrument was calibrated using pure silver sample before being used.

Microstructural characterization: The fractured surfaces of the produced composite samples were examined by Phenom ProX scanning electron microscope (SEM) operated at 15 Kv. Samples were mounted on to aluminium stubs with carbon tape and then sputter coated with platinum and palladium using Quorum coating machine (Q150res) to make them conductive prior to SEM observation.

Results and discussion

The XRF analysis showed that the main elements present in goat bone ash are calcium and phosphorus with 71.6 % and 16.6 %, respectively.

Mechanical behaviour

Figure 1 shows the variation of tensile strength with reinforcement and the neat sample. Three distinct stages were noticed where different trends were observed. From 2-6 wt. percent, the strength tends to increases as the reinforcement content increases while from 8-14 wt. percent, similar trend was observed but with a decrease in 14 wt. percent. These first two stages were characterized by decrease in tensile strength compared to the neat sample. This decrease in tensile strength might be due to either poor adhesion or direct contact of particles and void formation.16 However, from 16-20 wt. percent, contrast trend was noticed where the strength tends to decreases as the reinforcement content increases and higher enhancement of the tensile strength was obtain in this stage. It was observed that the sample with 16 wt. percent reinforcement has the highest tensile strength of 17.30 MPa followed by 18 wt. percent with a value of 10.16. This culminated to 74.6 % enhancement in tensile strength for the sample with 16 wt. percent reinforcement compared to the neat sample.

Figure 1 Variation of tensile strength with reinforcement and the neat sample.

The variation of tensile modulus with reinforcement and the neat sample was presented in Figure 2. The results show that the modulus was enhanced for the composite sample containing 16-20 wt. percent reinforcement. It was observed that the sample with 16 wt. percent reinforcement has the highest tensile modulus with a value of 298.93 MPa followed by 20 wt. percent with a value of 139.66 MPa. It can also be seen that the tensile modulus of the composite follow similar trend with the tensile strength in Figure 1. Similar effect of cow bone ash on tensile properties has been observed by Oladele IO16 in the case of bone ash and bone particulate reinforced polyester composites for biomedical applications.

Figure 2 Variation of tensile modulus with reinforcement and the neat sample.

Figure 3 shows the variation of flexural strength with reinforcement and the neat sample. The results showed that the flexural strength of the composites from 2-14 wt. percent was lower than that of the neat sample while that of 16-20 wt. percent was higher but in a decreasing order. The decrease in flexural strength within 2-14 wt. percent may be due to low amount of reinforcement, poor interfacial adhesion between the bone particulates and the epoxy matrix or non-uniform dispersion of the particulate within the epoxy that led to lower resistance to the applied flexural force leading to quick rupture.

Figure 3 Variation of flexural strength with reinforcement and the neat sample.

Nevertheless, it was observed from the results that, the sample with 16 wt. percent reinforcement has the highest flexural strength with a value of 7.07 MPa which amounted to 65 % enhancement compared to the neat sample followed by the sample with 18 wt. percent reinforcement with a value of 5.16 MPa.

From Figure 4, which shows the variation of flexural modulus with reinforcement and the neat sample, it was observed that the sample with 16 wt. percent reinforcement has the highest flexural modulus with a value of 61.49 MPa that culminated to 77.6 % enhancement in flexural modulus compared to the neat sample followed by the sample with 18 wt. percent reinforcement which has a value of 42.59 MPa and a 23 % enhancement. The response of the materials to flexural modulus was similar to that of the flexural strength. It was observed from the results that the properties were enhanced from 16-20 wt. percent reinforcement addition in a decreasing order.

Figure 4 Variation of flexural modulus with reinforcement and the neat sample.

The hardness values of the composites are presented in Figure 5. Similar response mode to other mechanical properties was observed with a slight difference. Here, it was observed that some samples within 2-14 wt. percent were seen to possess marginal improvement in hardness property compared to the neat sample. Still, 16-20 wt. percent range possess better improved hardness property. Sample with 16 wt. percent reinforcement has the highest hardness value of 39.7 HRA which may be due to uniform dispersion of particles and good bonding strength followed by the sample with 18 wt. percent reinforcement with a value of 37.6 HRA.

The enhanced mechanical properties, particularly within 16-20 wt. percent reinforcement content may be due to one or combinations of the following factors which are; higher weight reinforcement content added, good blending and wetting between the goat particulate and the epoxy matrix, reduced or absence of voids or sound interfacial bonding strength that allow easy transfer of load from the matrix to the reinforcement and, the presence of calcium and phosphorous in higher amount.

Figure 5 Variation of Rockwell hardness with reinforcement and the neat sample.

Wear behaviour

The behavior of the materials under the influence of load that tends to wear them is as presented in Figure 6. Three stages as observed in mechanical properties were also obvious here but with a difference. The best wear resistance was observed within the first stage where the resistance increases as the reinforcement content increases. Also, similar trend was obtained in the second stage but with lesser wear resistance when compared to the first stage. The third stage possess the least wear resistance and in an inverse order. Though, all the developed composites possess better wear resistance than the neat. In order words, the goat bone ash reduced the wear rate of the composite. From the results, 6 wt. percent possess the best wear resistance with wear index of 1.39 g followed by 4 wt. percent with a wear index value of 1.75 g compared to the neat sample with a wear index of 3.29 g.

Figure 6 Variation of wear index with reinforcement and the neat sample.

Considering the stage with the best mechanical properties and sample from 16 wt. percent that was the best among them, this sample was the best also with the highest wear resistance with a value of 2.71 g. This amounted to about 18 % enhancement, therefore, it implies that sample developed from 16 wt. percent is the best for this application(Table 1).

Composition (%)

Reinforcement (g)

Epoxy (g)

Hardener(g)

Neat

_

220

110

2

6.6

216

108

4

13.2

211

106

6

19.8

206

103

8

26.4

202

101

10

33

198

99

12

39.6

194

97

14

46.2

190

95

16

52.8

185

92

18

59.4

180

90

20

66

176

88

Table 1 Variation in percent composition and weight of produced samples.

Microstructure

Plate 1: Scanning electron microscope image of the fractured surface for (a). Neat epoxy (b). 8 wt. percent and (c). 16 wt. percent bone particulates reinforced epoxy composite showing particles dispersed in the epoxy matrix. Plates 1(a-c) show SEM micrograph for the neat epoxy material produced and sample from the two broad categories (2-14 and 16-20 wt. percent) of the developed composites where there is reduced and improved properties, respectively.

Plate 1 (a) revealed the fractured surface from the neat sample the presence of some voids due to entrapped air and crack was seen. This observed crack was due to the insufficient strength from the matrix to bear the applied load which led to crack propagation with the continuous application of load.

Plate 1(b) shows SEM micrograph for 8 wt. percent composite sample that represent the categories of samples with reduced strength compared to the neat. The whitish part indicates the bone particulates while the dark part indicates the epoxy matrix. Though, crack propagation was not noticed due the possibility of the goat bone particulate blocking and hindering the propagation of such failure mode, however, the reinforcement content were small and were not uniformly distributed. This may be part of the reasons for the weak mechanical properties obtained.

Plate 1 (c) shows SEM micrograph for the 16 wt. percent bone particulate reinforced epoxy composite produced that represent the improved composites categories. It was seen from the image that the reinforcement were present in high amount and were well dispersed. This was part of the reasons for the enhancement in properties obtained.

Plate 1 Scanning electron microscope image of the fractured surface for (A). Neat epoxy (B). 8 wt. % and (C). 16 wt. % bone particulates reinforced epoxy composite showing particles dispersed in the epoxy matrix.

Conclusion

The work has been carried out to investigate the possibility of exploiting goat bone as reinforcement in epoxy matrix for biomedical application. This animal bone is from one of the highly consumed meat in Nigeria which has been regarded as waste. From the research, the following conclusions have been made.

  1. The presence of calcium in higher proportion of about 71.6 % in calcined particulate goat bone as a natural reinforcement material confirm its suitability as a good reinforcement material in epoxy matrix for the development of composites for biomedical applications.
  2. Reinforcement of epoxy with 16-20 wt. percent particulate goat bone gave the best mechanical properties with 16 wt. percent emerging as the best among them.
  3. Wear resistance was highly enhanced within 2-6 wt. percent particulate goat bone reinforcement with 6 wt. percent evolving as the best weight fraction.
  4. Composite sample with best combination of mechanical and wear properties was 16 wt. percent goat bone particulate reinforced epoxy matrix composite. This feat positioned the sample as the most suitable material for biomedical application having met the structural conditions necessary.

Acknowledgements

None.

Conflict of interest

The author declares no conflict of interest.

References

  1. Rabie AB, Wong RW, Hagg U. Composite autogenous bone and demineralized bone matrices used to repair defects in the parietal bone of rabbits. Br J Oral Maxillofac Surg. 2000;38(5):565–570.
  2. Hench LL. Bioceramics. Journal of the American Ceramic Society. 1998;81(7):1705–1728.
  3. Goodrich JT, Sandler AL, Tepper O. A review of reconstructive materials for use in craniofacial surgery bone fixation materials, bone substitutes, and distracters. Childs Nerv Syst. 2012;28(9):1577–1588.
  4. Eglin D, Alini M. Degradable polymeric materials for osteosynthesis. Eur Cell Mater. 2008;16:80–91.
  5. Sumner DR. Long-term implant fixation and stress-shielding in total hip replacement. J Biomech. 2015;48(5):797–800.
  6. Manivasagam G, Dhinasekaran D, Rajamanickam A. Biomedical implants: corrosion and its prevention-a review. Recent Patents on Corrosion Science. 2010;2:40–54.
  7. Park JP, Bronzino JD. Biomaterials: principles and applications. In: Kon Kim Y, et al. editors. Metallic Biomaterials. USA: CRC Press LLC; 2003. p. 1–20.
  8. Murali MR, Mohana KK, Ratna AV. Fabrication and testing of natural fibre composites: Vakka, sisal, bamboo and banana. Materials & Design. 2010;31(1):508–513.
  9. Black J. Biological Performance of Materials: Fundamentals of Biocompatibility. 2nd ed. New York: Marcel Dekker; 1992. 520 p.
  10. Hermawan H, Ramdan D, Djuansjah JRP. Biomedical engineering-from theory to applications. Reza Fazel-Rezai, editor. Metals for Biomedical Applications. Rijeka: InTech; 2011. p. 411–430.
  11. Oladele IO, Adewole TA. Influence of cow bone particle size distribution on the mechanical properties of cow bone-reinforced polyester composites. Hindawi Publishing Corporation Biotechnology Research International. 2013;2013:1–5.
  12. Oladele IO, Olajide JL, Amujede M. Wear resistance and mechanical behaviour of epoxy/mollusk shell biocomposites developed for structural applications. Tribology in Industry. 2016;38(3):347–360.
  13. Oladele IO, Agbabiaka OG. Investigating the influence of mercerization treatment of sisal fiber on the mechanical properties of reinforced polypropylene composites and modeling of the properties. Fibers and Polymers. 2015;16(3):650–656.
  14. Oladele, IO, Adewumi AO, Bello OR. Wear and thermal properties of hybrid palm kernel fruit reinforced polyester composites. ANNALS of Faculty of Engineering Hunedoara-International Journal of Engineering Fiscicule. 2015;13(4):69–74.
  15. Agunsoye JO, Talabi S I, Awe O, et al. Mechanical properties and tribological behaviour of recycled polyethylene/cow bone particulate composite. Journal of Materials Science Research. 2013;2(2):41.
  16. Oladele IO. Development of bone ash and bone particulate reinforced polyester composites for biomedical applications. Leonardo Electronic Journal of Practices and Technologies. 2013;22:15–26.
Creative Commons Attribution License

©2016 Oladele, et al. This is an open access article distributed under the terms of the, which permits unrestricted use, distribution, and build upon your work non-commercially.