Water apply and distribution systems for drip irrigation as guarantee of rational use of water face tclimaticchance study case

Pável Vargas Rodríguez,1 Rafael Miguel Pacheco Moya,1 Abel Dorta Armaignac,1 Ariel Quintana Suarez2

1Department of Hydraulic Engineering, Eastern University, Cuba
2Department of UEB Consulting and Design, ENPA, Cuba

Correspondence: Rafael Miguel Pacheco Moya, Department of Hydraulic Engineering, Eastern University, Santiago de Cuba

Received: October 01, 2018 | Published: November 8, 2018

Citation: Rodríguez PV, Moya RMP, Armaignac AD, et al. Water apply and distribution systems for drip irrigation asguarantee of rational use of water face tclimaticchance study case. Fluid Mech Res Int J. 2018;2(5):211-217. DOI: 10.15406/fmrij.2018.02.00040

Download PDF

Abstract

An analysis of water consumption for all uses in Cuba shows that the volume of water planned for the whole country, agricultural activities consume 50% each year and approximately 40% of this volume been used for irrigation of the rice crop, Dorticos (2012). Surface irrigation systems classified as those with the lowest efficiency in water use, with average values lower than 60%; being the lowest among all the irrigation techniques used in the country. This situation justifies the use of more efficient irrigation techniques, which propitiate the highest crop yields and contribute to mitigate the effects of climate change. In the paper are compared, three variants design of drip irrigation system in citrus crops, for a real case study in the central region of Cuba: Using the procedures followed from the field tests; using tabulated values proposed by other authors; and applying an alternative procedure used in the design practice of these irrigation systems. The results demonstrate the need to carry out field tests as a premise to design drip irrigation systems and as a guarantee of the rational use of water and energy in the face of climate change.

Keywords: localized irrigation, drip emitter, flow, volume, wet bulb

Introduction

Due to its regular nature, laminar flow is simpler to analyze than turbulent flow. However, most of the problems that arise in the design of pressurized hydraulic networks belong to the domain of the turbulent regime. The identification of one or the other is done through the Reynolds Number (Re). Osborne Reynolds (1842-1867) was born in Belfast, Ireland, and developed experiments that allowed him to present a series of theories that are still valid today.

Re= V× ι MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaeOuai aadwgacaaI9aqcfa4aaSaaaOqaaKqzGeGaamOvaiabgEna0kabgwGi gdGcbaqcLbsacqaH5oqAaaaaaa@40EA@ (1)

Donde:

V.-Average speed in the pipe (m/s) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq=Jc9 vqaqpepm0xbba9pwe9Q8fs0=yqaqpepae9pg0FirpepeKkFr0xfr=x fr=xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaqcLbsacaGGOa GaamyBaiaac+cacaWGZbGaaiykaaaa@3A7B@

ϕ MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaeqy1dy gaaa@3842@ -Inside diameter ofthe pipe (m)

U.-Kinematic viscosity ( m 2 /s) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq=Jc9 vqaqpepm0xbba9pwe9Q8fs0=yqaqpepae9pg0FirpepeKkFr0xfr=x fr=xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaqcLbsacaGGOa GaamyBaSWaaWbaaWqabeaacaaIYaaaaKqzGeGaai4laiaadohacaGG Paaaaa@3BFF@

Re2000 MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamOuai aadwgacqGHKjYOcaaIYaGaaGimaiaaicdacaaIWaaaaa@3CDA@ Laminar flow

2000<Re<4000 MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGOmai aaicdacaaIWaGaaGimaiaaiYdacaWGsbGaamyzaiaaiYdacaaI0aGa aGimaiaaicdacaaIWaaaaa@3F9D@ Transitional Regime

Re4000 MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamOuai aadwgacqGHLjYScaaI0aGaaGimaiaaicdacaaIWaaaaa@3CED@ Turbulent flow

4000Re10/(ε/φ) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGinai aaicdacaaIWaGaaGimaiabgsMiJkaadkfacaWGLbGaeyizImQaaGym aiaaicdacaaIVaGaaGikaiabew7aLjaai+cacqaHgpGAcaaIPaaaaa@4641@ Smooth Turbulent Flow

10/(ε/φ)<Re<500/(ε/φ) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGymai aaicdacaaIVaGaaGikaiabew7aLjaai+cacqaHgpGAcaaIPaGaaGip aiaadkfacaWGLbGaaGipaiaaiwdacaaIWaGaaGimaiaai+cacaaIOa GaeqyTduMaaG4laiabeA8aQjaaiMcaaaa@49E5@ Transitional Turbulent Flow.

ε MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaeqyTdu gaaa@3821@ : Equivalent absolute roughness of the pipe wall, m. MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaeyBai aai6caaaa@3822@

δL MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaeqiTdq Maaeitaaaa@38EE@ : Thickness of the boundary layer, m. MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaeyBai aai6caaaa@3822@

In pressurized irrigation systems the water is distributed by means of generally circular pipes, a full section, it is applied to the crops by means of emission devices that deliver the flow by dissipating the energy. According to Caupers and Junior1, the formulation of Torricelli offers an accurate approach to estimate the flow rate delivered by an irrigation emitter; it is valid for large tanks with an outlet in the sidewall Figure 1.

Figure 1 Estimate of the Speed in holes.

Applying Bernoulli between A and B and taking as reference Z = 0. Where B is the contracted section and A and B are opento the atmosphere P =patm.

Z A + P A γ + V A 2 2g = Z B + P B γ + V B 2 2g . MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamOwaK qbaoaaBaaaleaajugWaiaadgeaaSqabaqcLbsacqGHRaWkjuaGdaWc aaGcbaqcLbsacaWGqbqcfa4aaSbaaSqaaKqzadGaamyqaaWcbeaaaO qaaKqzGeGaeq4SdCgaaiabgUcaRKqbaoaalaaakeaajugibiaadAfa lmaaDaaabaqcLbmacaWGbbaaleaajugWaiaaikdaaaaakeaajugibi aaikdacaWGNbaaaiabg2da9iaadQfajuaGdaWgaaWcbaqcLbmacaWG cbaaleqaaKqzGeGaey4kaSscfa4aaSaaaOqaaKqzGeGaamiuaKqbao aaBaaaleaajugWaiaadkeaaSqabaaakeaajugibiabeo7aNbaacqGH RaWkjuaGdaWcaaGcbaqcLbsacaWGwbWcdaqhaaqaaKqzadGaamOqaa WcbaqcLbmacaaIYaaaaaGcbaqcLbsacaaIYaGaam4zaaaacaaIUaaa aa@62ED@

Z: position height

p γ MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq=Jc9 vqaqpepm0xbba9pwe9Q8fs0=yqaqpepae9pg0FirpepeKkFr0xfr=x fr=xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaqcfa4aaSaaaO qaaKqzGeGaamiCaaGcbaqcLbsacqaHZoWzaaaaaa@3A62@ :pressure loading

v 2 2g MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq=Jc9 vqaqpepm0xbba9pwe9Q8fs0=yqaqpepae9pg0FirpepeKkFr0xfr=x fr=xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaqcfa4aaSaaae aajugibiaadAhajuaGdaahaaqabeaajugWaiaaikdaaaaajuaGbaqc LbsacaaIYaGaam4zaaaaaaa@3D7D@ :load at speed

Considering

P A γ =0 t ; V A 2 2g =0; P B γ =0. MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqbaoaalaaake aajugibiaadcfalmaaBaaabaqcLbmacaWGbbaaleqaaaGcbaqcLbsa cqaHZoWzaaGaaGypaiaaicdajuaGdaWgaaWcbaqcLbsacaWG0baale qaaKqzGeGaai4oaKqbaoaalaaakeaajugibiaadAfalmaaDaaabaqc LbmacaWGbbaaleaajugWaiaaikdaaaaakeaajugibiaaikdacaWGNb aaaiaai2dacaaIWaGaaG4oaKqbaoaalaaakeaajugibiaadcfajuaG daWgaaWcbaqcLbmacaWGcbaaleqaaaGcbaqcLbsacqaHZoWzaaGaaG ypaiaaicdakiaai6caaaa@5576@ Thus:

V B = 2g×( Z A Z B ) 2 MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamOvaS WaaSbaaeaajugWaiaadkeaaSqabaqcLbsacaaI9aqcfa4aaOqaaOqa aKqzGeGaaGOmaiaadEgacqGHxdaTcaaIOaGaamOwaKqbaoaaBaaale aajugWaiaadgeaaSqabaqcLbsacqGHsislcaWGAbqcfa4aaSbaaSqa aKqzadGaamOqaaWcbeaajugibiaaiMcaaSqaaKqzadGaaGOmaaaaaa a@4C63@

V B = 2gH 2 MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamOvaK qbaoaaBaaaleaajugWaiaadkeaaSqabaqcLbsacaaI9aqcfa4aaOqa aOqaaKqzGeGaaGOmaiaadEgacaWGibaaleaajugWaiaaikdaaaaaaa@4106@ (2)

The evolution of these emission devices, which take water from pressure pipes has been extremely wide (from localized irrigation emitters that deliver less than 2L/h to spray nozzles that deliver more than 100L/h), hydraulic operation of the same varies from the Laminar regime to the full Turbulence, López Sánchez.2 Starting from (2), you can define the flow rate delivered by a spray nozzle by means of:

Q=Cc×Cv×Ao× 2gH MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamyuai aai2dacaWGdbGaam4yaiabgEna0kaadoeacaWG2bGaey41aqRaamyq aiaad+gacqGHxdaTjuaGdaGcaaGcbaqcLbsacaaIYaGaam4zaiaadI eaaSqabaaaaa@4740@ (3)

In which, Cc×Cv MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaam4qai aadogacqGHxdaTcaWGdbGaamODaaaa@3C04@ is the sprinkler discharge coefficient (Cd) corrected as a function of the coefficient of the jet contraction and the speed coefficient respectively and Cd×Ao× 2g MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaam4qai aadsgacqGHxdaTcaWGbbGaam4BaiabgEna0Mqbaoaakaaakeaajugi biaaikdacaWGNbaaleqaaaaa@40FD@ is a KD constant for each sprinkler as a function of the geometric characteristics. Admitting that the device works in a Turbulent flow (x = 0.5), equation (2) can be transformed into:

Q=Kd× H X MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamyuai aai2dacaWGlbGaamizaiabgEna0kaadIeajuaGdaahaaWcbeqaaKqz adGaamiwaaaaaaa@3F7A@ (4)

Where (x) is the sprinkler discharge exponent. According to López Sánchez2, the value of (x) would be between 0.5 and 1.0, depending on whether the emission device works in Laminar or Turbulent flow. However due to the device that allows a discharge limitation with the increasing pressure (as well as the auto-compensating drip irrigation emitters), the value of (x) can even be less than 0.5. The next Figure 2 shows the flow rate variations of the emitter as a function of the pressure variation for values 0x1 MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq=Jc9 vqaqpepm0xbba9pwe9Q8fs0=yqaqpepae9pg0FirpepeKkFr0xfr=x fr=xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaqcLbsacaaIWa GaeyizImQaamiEaiabgsMiJkaaigdaaaa@3C61@ , emitter flow of 4L/h and working pressure 8H12 MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq=Jc9 vqaqpepm0xbba9pwe9Q8fs0=yqaqpepae9pg0FirpepeKkFr0xfr=x fr=xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaqcLbsacaaI4a GaeyizImQaamisaiabgsMiJkaaigdacaaIYaaaaa@3CF5@ (mca) Table 1.

Flow regime

(x)

Type of issuer

Variable duct

0

Auto-compensating

0.1

0.2

0.3

Vertical flow

0.4

Vortex emitters

Rugged Turbulent Flow.

0.5

Orifice and Labyrinth emitters

Partial Turbulent Flow.

0.6

Long Conduit and Spiral emitters

0.7

Partial Laminar Flow.

0.8

Micro tube

0.9

Perfectly Laminar Flow

1

Capillary flow

Table 1 Exponent of discharge values proposed by Boswell3

Figure 2 Flow variations of the emitter, Boswell.3

According to Boswell3, the real value of the exponent (x) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGikai aadIhacaaIPaaaaa@38DC@ for a given emitter can be determined experimentally by working the emitter at two different pressures ( H 1 y H 2 ) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGikai aadIealmaaBaaabaqcLbmacaaIXaaaleqaaKqzGeGaamyEaiaadIea lmaaBaaabaqcLbmacaaIYaaaleqaaKqzGeGaaGykaaaa@3FD6@ . Within the working pressure range of the emitter and carefully measuring the flow rates ( Q 1 y Q 2 ) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGikai aadgfajuaGdaWgaaWcbaqcLbsacaaIXaaaleqaaKqzGeGaamyEaiaa dgfajuaGdaWgaaWcbaqcLbsacaaIYaaaleqaaKqzGeGaaGykaaaa@3FC6@ , then the pairs are drawn on logarithmic paper ( H 1 ; Q 1 )y( H 2 ; Q 2 ) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGikai aadIeajuaGdaWgaaWcbaqcLbmacaaIXaaaleqaaKqzGeGaaGjbVlaa iUdacaaMe8UaamyuaSWaaSbaaeaajugWaiaaigdaaSqabaqcLbsaca aIPaGaaeyEaiaaiIcacaWGibqcfa4aaSbaaSqaaKqzadGaaGOmaaWc beaajugibiaaysW7caaI7aGaaGjbVlaadgfalmaaBaaabaqcLbmaca aIYaaaleqaaKqzGeGaaGykaaaa@511E@ and the slope ofthe line drawn between the two points is measured. It can also be obtained by algebraically deriving equation (4).

X= log( Q 1 Q 2 ) log( H 1 H 2 ) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamiwai aai2dajuaGdaWcaaGcbaqcLbsaciGGSbGaai4BaiaacEgacaaIOaqc fa4aaSaaaOqaaKqzGeGaamyuaSWaaSbaaeaajugWaiaaigdaaSqaba aakeaajugibiaadgfajuaGdaWgaaWcbaqcLbmacaaIYaaaleqaaaaa jugibiaaiMcaaOqaaKqzGeGaciiBaiaac+gacaGGNbGaaGikaKqbao aalaaakeaajugibiaadIealmaaBaaabaqcLbmacaaIXaaaleqaaaGc baqcLbsacaWGibWcdaWgaaqaaKqzadGaaGOmaaWcbeaaaaqcLbsaca aIPaaaaaaa@536C@ (5)

The constant (kd) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGikai aadUgacaWGKbGaaGykaaaa@39B8@ can also be obtained by clearing (4):

Kd= Q H χ MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaam4sai aadsgacaaI9aqcfa4aaSaaaOqaaKqzGeGaamyuaaGcbaqcLbsacaWG ibqcfa4aaWbaaSqabeaajugWaiabeE8aJbaaaaaaaa@400D@ (6)

According to López Sánchez2 during the hydraulic design of irrigation plots in pressurized systems, in order to ensure adequate emission uniformity, it is important to analyze the dependencies between the relative variations of flow and pressure. In this sense the elementary variation of the flow (dQ10%) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGikai aadsgacaWGrbGaeyizImQaaGjbVlaaigdacaaIWaGaaGyjaiaaiMca aaa@3F04@ , corresponding to an elementary variation of the pressure (dH), can also be obtained from (4):

dQ=Kd×χ× H x1 dH MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamizai aadgfacaaI9aGaam4saiaadsgacqGHxdaTcqaHhpWycqGHxdaTcaWG ibqcfa4aaWbaaSqabeaajugWaiaadIhacqGHsislcaaIXaaaaKqzGe GaamizaiaadIeaaaa@483E@ (7)

In design practice, it is common to admit a relative variation ofthe flow rate (dQ10%) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGikai aadsgacaWGrbGaeyizImQaaGjbVlaaigdacaaIWaGaaGyjaiaaiMca aaa@3F04@ , referred to the nominal or design value ofthe emission devices, thus: (dQ/Q0.10) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGikai aadsgacaWGrbGaaG4laiaadgfacqGHKjYOcaaIWaGaaGOlaiaaigda caaIWaGaaGykaaaa@3FC9@ . So that, as in full turbulence regime (x=0.5) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGikai aadIhacaaI9aGaaGimaiaai6cacaaI1aGaaGykaaaa@3BD4@ ; the relative pressure variation also referred to the nominal value ofthe emission device is obtained by substituting (6) in (7):

dQ= Q H χ ×x× H x1 ×dH MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamizai aadgfacaaI9aqcfa4aaSaaaOqaaKqzGeGaamyuaaGcbaqcLbsacaWG ibWcdaahaaqabeaajugWaiabeE8aJbaaaaqcLbsacqGHxdaTcaWG4b Gaey41aqRaamisaKqbaoaaCaaaleqabaqcLbmacaWG4bGaeyOeI0Ia aGymaaaajugibiabgEna0kaadsgacaWGibaaaa@4EF6@

dH= dQ Q × 1 χ × H χ H x1 MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamizai aadIeacaaI9aqcfa4aaSaaaOqaaKqzGeGaamizaiaadgfaaOqaaKqz GeGaamyuaaaacqGHxdaTjuaGdaWcaaGcbaqcLbsacaaIXaaakeaaju gibiabeE8aJbaacqGHxdaTjuaGdaWcaaGcbaqcLbsacaWGibWcdaah aaqabeaajugWaiabeE8aJbaaaOqaaKqzGeGaamisaKqbaoaaCaaale qabaqcLbmacaWG4bGaeyOeI0IaaGymaaaaaaaaaa@50D6@

dH=0.2H MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamizai aadIeacaaI9aGaaGimaiaai6cacaaIYaGaamisaaaa@3BF2@ (8)

If Laminar Flow (x=1) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGikai aadIhacaaI9aGaaGymaiaaiMcaaaa@3A5E@ , then:

dH=0.1H MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamizai aadIeacaaI9aGaaGimaiaai6cacaaIXaGaamisaaaa@3BF1@ (9)

This highlights the influence of the type of emission device and the flow regime on the emission uniformity of the emitters in the irrigation plot. However, the experience in the design has shown that the above is not the only criterion that should be considered when designing an irrigation plot. In the design of drip irrigation systems the criteria are more demanding, for these cases the criterion of uniformity of Kristiansen is not applicable, for them a new coefficient of uniformity (CU) is defined, which can be used for the evaluation of facilities in operation as well as for the design of new facilities. This parameter is a condition that is imposed in the agronomic design and correlates constructive and hydraulic factors, was suggested by (ASAE EP405), cited by Boswell3 and accepted by the US Soil Conservation Service.

CU=[(1 1.27×Cvf 2 e )×( Qm ι n Qmed )×100] MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaam4qai aadwfacaaI9aGaaG4waiaaiIcacaaIXaGaeyOeI0scfa4aaSaaaOqa aKqzGeGaaGymaiaai6cacaaIYaGaaG4naiabgEna0kaadoeacaWG2b GaamOzaaGcbaqcLbmacaaIYaqcfa4aaSbaaSqaaKqbaoaakaaaleaa jugibiaadwgaaSqabaaabeaaaaqcLbsacaaIPaGaey41aqRaaGikaK qbaoaalaaakeaajugibiaadgfacaWGTbGafqyUdKMbauaacaWGUbaa keaajugibiaadgfacaWGTbGaamyzaiaadsgaaaGaaGykaiabgEna0k aaigdacaaIWaGaaGimaiaai2faaaa@5DB5@ (10)

Donde:

Cvf MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaam4qai aadAhacaWGMbaaaa@3928@ . ‒Fabrication variation coefcient (t×1) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGikai aabshacqGHxdaTcaaIXaGaaGykaaaa@3BA8@ .

e MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamyzaa aa@3764@ . ‒Emitters Number wetting the same plant (u).

Qmin. MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamyuai aad2gacaWGPbGaamOBaiaai6cacqGHsislaaa@3BC8@ Minimum admissible flow in the irrigation plot (L/h) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaeikai aabYeacaaIVaGaaeiAaiaabMcaaaa@3A44@ .

Qmed. - Average flow ofthe emitters in the irrigation plot (L/h) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGikai aabYeacaaIVaGaaeiAaiaaiMcaaaa@3A52@ .

The term (1 1.27×Cνf 2 e ) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGikai aaigdacqGHsisljuaGdaWcaaGcbaqcLbsacaaIXaGaaGOlaiaaikda caaI3aGaey41aqRaam4qaiabe27aUjaadAgaaOqaaKqzadGaaGOmaK qbaoaaBaaaleaajuaGdaGcaaWcbaqcLbsacaWGLbaaleqaaaqabaaa aKqzGeGaaGykaaaa@489A@ groups the constructive factors.

The term ( Qmin Qmed ) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGikaK qbaoaalaaakeaajugibiaadgfacaWGTbGaamyAaiaad6gaaOqaaKqz GeGaamyuaiaad2gacaWGLbGaamizaaaacaaIPaaaaa@40F3@ groups the hydraulic factors.

Three reasons justify the use of this expression (10) instead of the one used in the design of sprinkler irrigation systems (8):

  1. The fact that the outlet diameter of the drip emitters is much smaller than the diameter of the sprinkler emitters; generally outlet diameter value oscillates between 0.8 ≤ s ≤ 1.2mm, implies that the risk of obturation is much greater in drip irrigation emitters.
  2. Due to the wear occurred by the molds during the manufacturing process, not all drip emitters leave the factory with the same outlet diameter, these affects the uniformity discharge of the emitters in the irrigation plot, then, considering the number of emitters wetting the same plant (e) when estimating (CU); the constructive factor is taken into account with greater rigor in the localized irrigation systems.
  3. In drip irrigation systems the incidence of winds in the shape and dimensions of the wet bulbs that are generated is significantly lower than sprinkler irrigation. Considering the hydraulic factor during the design procedure, the relationship between the minimum permissible flow rate in the plot and the nominal flow or design of the emitter have to taking into account, by means of to estimate the losses due to frictions that take place in the network of pipes that make up the irrigation plot, as well as the topographic differences due to the relief; By means of checking that the minimum pressure within the irrigation plot is greater than or equal to a minimum value that is calculated in the pressure tolerance. With the technological advances achieved, the hydraulic component of (CU) has been significantly improved with the auto compensating emitters. However, in spite of the wide range of these that exist in the market, the risk of obturation is still a problem not totally solved and the solutions usually involve expensive filtering systems depending on the quality of the irrigation water.

Methods and procedures

Pizarro4 states; to guarantee a soil moisture content corresponding to the crop water requirements, is important to delimit the value of (e) that guarantees the minimum percentage of wetting (PHum) around the root system; as well as to define the volume delivered by the emitter (Ve) and made available to the plant very close to this area: (90% Prad Pb MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaeyizIm QaamiuaiaadkgacqGHKjYOaaa@3BA0@ 120%Prad). Also refers that the choice (PHum) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGikai aadcfacaWGibGaamyDaiaad2gacaaIPaaaaa@3B6D@ is an important issue since at high values, increases the security of the system due to the greater volume of soil moist explored by the roots, facilitating the absorption of water and nutrients; however, high values of (PHum) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaGikai aadcfacaWGibGaamyDaiaad2gacaaIPaaaaa@3B6D@ also increase the cost of the installation, this aspect being as well as the risk of obturation of the emitters the main drawbacks of this irrigation method. Another important issue is the wetted area by the drip emitter, since the shape and dimensions of the wet bulb generated by these emitters depends on multiple factors, among them the soil texture, the degree of stratification, the irrigation depth, the frequency and timing irrigation and others. For the purposes of design, the estimation of the area wetted by a drip emitter can be done by three procedures: the use of professional software that allows simulating the behavior of the wetting bulb, the use of tables made by other authors and based on the results obtained from field tests. According to Pizarro4 the use of modeling software is faced with the mathematical difficulty to integrate the differential equations that are reached after its analysis, as well as to establish its limits of integration and to estimate the hydraulic diffusivity that is the parameter that defines the variation of moisture contents in conditions of non-saturation. Currently there are some of these simulation models, but the difficulty to obtain the data that must be provided to the same together with the acquisition price, makes this not for the moment a viable solution for design purposes. Also refers, that the use of tables will be more inappropriate the more factors are ignored, due to the difficulty of quantifying from the soil properties other important parameters such as the degree of stratification, stoniness and other related to the soil moisture content. Therefore, although very complete tables are available in certain data, their use will suffer from the necessary precision for the design, so they should always be used with great caution. Table 2 that follows shows an example. The use of the results of the field test is currently the most rigorous procedure to design drip irrigation systems. The design is made by trial and error starting from establishing the limits in depth of the wet bulb, foreseeing that the same when at least located very close to the area of dense branching of the roots of the plant. This can be achieved through:

90% Prad p MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaiabgsMiJkaadc hacqGHKjYOaaa@3A4A@ 120% Prad (11)

Next, the value of (p) between these limits is selected from the results of the field test and the corresponding values of (Ve) and (r) are noted. From (r) the surface moistened by the emitter is calculated by means of:

Ae=π× r 2 MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamyqai aadwgacaaI9aGaeqiWdaNaey41aqRaamOCaSWaaWbaaeqabaqcLbma caaIYaaaaaaa@3FD3@ (12)

Then the minimum number of issuers is determined, which guarantees that the percentage of wetted surface of each plant is higher than a minimum that has been established by several authors:

e Amp×PHmin 100×Ae MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamyzai abgwMiZMqbaoaalaaakeaajugibiaadgeacaWGTbGaamiCaiabgEna 0kaadcfacaWGibGaamyBaiaadMgacaWGUbaakeaajugibiaaigdaca aIWaGaaGimaiabgEna0kaadgeacaWGLbaaaaaa@4A29@ (13)

Keller5 recommends the following minimum values of percentage of wet area for the case of trees. Later Torralba7,8 proposes orientative values of (PHmín) for Cuba conditions Table 3.

Depth of roots and soil texture

Degree of soil stratification

Homogeneous

Stratified

In layers

Wet diameter (m)

DEPTH = 0.80m

Light

0.5

0.8

1.1

Media

1

1.25

1.7

Heavy

1.1

1.7

2

DEPTH = 1.70m

Light

0.8

1.5

2

Media

1.25

2.25

3

Heavy

1.7

2

2.5

Table 2 Wet diameter by an emitter 4L/h, Keller6

Keller6

Torralba7

 

WEATHER

PHmin(%)

CROPS

PHmin(%)

Wet

20

Citrus and fruits

25–35*

Arid

33

Banana

40–60*

Coffee

30–40*

Vegetables

70–90*

 

 

Hydroponics y Gardens

100

Table 3 Orientate values of (PH mín) for the design of Drip irrigation systems

The percentages vary from the lower value to the higher when increasing the aridity of the climate and the lightness in texture and stony soil. The frequency of irrigation can be estimated according to the relationship between the volume of water needed by the plant and the volume of water applied by the emitter, which is measured experimentally during the field test and corresponds to the depth and the diameter of the appropriate wet bulb according to the properties of the soil. That is deduced from:

e×Ve=l×Nt MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamyzai abgEna0kaadAfacaWGLbGaaGypaiaadYgacqGHxdaTcaWGobGaamiD aaaa@40DB@ (14)

The irrigation timing depends on the total water needs and the installed flow per plant this depends on the disposition of emitters that is adopted in relation to the row of plants, the irrigation timing is approximated by excess in fractions of quarter hour to facilitate irrigation scheduling, it can be estimated from:

Tr= NT e×Qe MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamivai aadkhacaaI9aqcfa4aaSaaaOqaaKqzGeGaamOtaiaadsfaaOqaaKqz GeGaamyzaiabgEna0kaadgfacaWGLbaaaaaa@414E@ (15)

The schedule with interline emitters are not recommended for the case of trees, because it creates a wet strip that is only suitable in dense plantations with not very extensive root systems; it is more justified in the case of irrigation water management in the presence of salts. The dispositions with interline and two lateral emitters per row of plant are not recommended, because it doubles the length of the lateral pipes. The irrigation water depth is calculated based on the number of emitters that moisten the same plant and the volume delivered by each emitter, which have been noted the specifications described above, it is derived from:

DT=e×Ve=e×Qe×Tr MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaamirai aadsfacaaI9aGaamyzaiabgEna0kaadAfacaWGLbGaaGypaiaadwga cqGHxdaTcaWGrbGaamyzaiabgEna0kaadsfacaWGYbaaaa@4718@ (16)

In order to provide a practical approach to the aforementioned, will address the complete design of a rotational unit of localized irrigation, using auto-compensating drippers, to benefit crops of Orange. The design will be carried out by three different procedures but using the same data that define the Water - Soil - Plant - Climate complex for the three variants; so that conclusions can be established to demonstrate the validity of the investigation.

Characterization of the study area

The study case covers a gross area of 1.20 ha, consists of four rectangular irrigation plots of (80m × 200m), located in pairs around the control station. In it, the pumping installation will be concentrated together with the filtering system in order to facilitate irrigation automation. The irrigation plots will be separated at 10m to facilitate the work of harvesting, repair and maintenance of the irrigation system. A perimeter path of 5m is foreseen to facilitate communication with other areas with irrigation perspectives. An underground source of water supply will be assumed, with an authorized flow to extract enough for the irrigation of the proposed crops. Likewise, a coefficient of uniformity CU = 90% will be assumed for the design and the plots will be 200m long. The relief is quite flat, so the pipe network slopes will not be taken into account in the design to facilitate calculations. The design procedure of the first and second variants is conceived based on the procedure proposed by Keller & Rodrigo5 the calculation will be made from the data of the field test referred in the Table 4 & 5. For the third variant, an alternative procedure will be used, which is currently used due to the impossibility of performing the field tests.

Water

 Ground

Plant

Weather

 Aggregates of irrigation

CEar=0.7dS/m MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaiaayIW7jugibi aaysW7caWGdbGaamyraiaadggacaWGYbGaaGypaiaaicdacaaIUaGa aG4naiaadsgacaWGtbGaaG4laiaad2gacaaMi8oaaa@44FE@  
Suitable for crop irrigation 

CEes=1.7dS/m; Corresponding to 100% theproduction. Mediumtexture (Efap.=90%) MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeqbaeaabu qaaaaakeaajugibiaayIW7caaMe8Uaam4qaiaadweacaWGLbGaam4C aiaaysW7caaI9aGaaGymaiaai6cacaaI3aGaamizaiaadofacaaIVa GaamyBaiaaiUdacaaMi8oakeaajugibiaayIW7caWGdbGaam4Baiaa dkhacaWGYbGaamyzaiaadohacaWGWbGaam4Baiaad6gacaWGKbGaam yAaiaad6gacaWGNbaeaaaaaaaaa8qacaGGGcWdaiaadshacaWGVbWd biaacckapaGaaGymaiaaicdacaaIWaGaaGyjaiaayIW7aOqaaKqzGe GaaGjcVlaaysW7caWG0bGaamiAaiaadwgacaaMe8UaamiCaiaadkha caWGVbGaamizaiaadwhacaWGJbGaamiDaiaadMgacaWGVbGaamOBai aai6cacaaMi8oakeaajugibiaayIW7caWGnbGaamyzaiaadsgacaWG PbGaamyDaiaad2gacaaMe8UaamiDaiaadwgacaWG4bGaamiDaiaadw hacaWGYbGaamyzaiaayIW7aOqaaKqzGeGaaGjcVlaaiIcacaWGfbGa amOzaiaadggacaWGWbGaaGOlaiaaysW7caaI9aGaaGyoaiaaicdaca aILaGaaGykaiaayIW7aaaaaa@9274@

Prof.rad.=1.10m M.Siembra=8×4 Kc=1.2 copa=4.6m MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeqbaeaabq qaaaaakeaajugibiaayIW7caWGqbGaamOCaiaad+gacaWGMbGaaGOl aiaaysW7caWGYbGaamyyaiaadsgacaaIUaGaaGjbVlaai2dacaaIXa GaaGOlaiaaigdacaaIWaGaaeyBaiaayIW7aOqaaKqzGeGaaGjcVlaa d2eacaaIUaGaaGjbVlaadofacaWGPbGaamyzaiaad2gacaWGIbGaam OCaiaadggacaaMe8UaaGypaiaaiIdacqGHxdaTcaaMe8UaaGinaiaa yIW7aOqaaKqzGeGaaGjcVlaaysW7caWGlbGaam4yaiaai2dacaaIXa GaaGOlaiaaikdacaaMi8oakeaajugibiaayIW7caaMe8UaeyybIySa aGjbVlaadogacaWGVbGaamiCaiaadggacaaI9aGaaGinaiaai6caca aI2aGaamyBaiaayIW7aaaaaa@7879@

Ev=7mm/d Kp=0.9 MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeqbaeaabi qaaaGcbaqcLbsacaaMi8UaaGjbVlaadweacaWG2bGaaGypaiaaiEda caWGTbGaamyBaiaai+cacaWGKbGaaGjcVdGcbaqcLbsacaaMi8UaaG jbVlaadUeacaWGWbGaaGypaiaaicdacaaIUaGaaGyoaiaayIW7aaaa aa@4CAA@

0.2Qe4L/h 50He400kPa Cvf=1.3%; Tod=16h PHmin=40%; a=20% MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeqbaeaaby qaaaaakeaajugibiaayIW7caaMe8UaaGimaiaai6cacaaIYaGaaGjb VlabgsMiJkaaysW7caWGrbGaamyzaiabgsMiJkaaysW7caaI0aGaam itaiaai+cacaWGObGaaGjcVdGcbaqcLbsacaaMi8UaaGjbVlaaiwda caaIWaGaeyizImQaaGjbVlaadIeacaWGLbGaeyizImQaaGjbVlaais dacaaIWaGaaGimaiaadUgacaWGqbGaamyyaiaayIW7aOqaaKqzGeGa aGjcVlaaysW7caWGdbGaamODaiaadAgacaaI9aGaaGymaiaai6caca aIZaGaaGyjaiaacUdacaaMi8oakeaajugibiaayIW7caaMe8Uaamiv aiaad+gacaWGKbGaaGypaiaaigdacaaI2aGaamiAaiaayIW7aOqaaK qzGeGaaGjcVlaaysW7caWGqbGaamisaiaad2gacaWGPbGaamOBaiaa ysW7caaI9aGaaGinaiaaicdacaaILaGaai4oaiaayIW7aOqaaKqzGe GaaGjcVlaaysW7caaMe8Uaamyyaiaai2dacaaIYaGaaGimaiaaiwca caaMi8oaaaaa@9009@

Table 4 Basics data for the solution of the variants

Fleld test

Ve r P

(L) (m) (m)

4

0.25

0.3

8

0.33

0.39

12

0.4

0.5

16

0.59

0.63

20

0.76

0.69

24

0.8

0.9

28

0.83

1.05

32

0.86

1.22

36

0.9

1.4

40

0.91

1.6

𝐶𝐸𝑎𝑟.- Electric conductivity of irrigation water.

 

𝐶𝐸𝑒𝑠.- Electric conductivity of the soil saturation extract.

𝐸𝑓𝑎𝑝 - Application efficiency.

Prof. Rad.- Ruth depth.

𝐾𝑐.- Crop coefficient. 𝑐𝑜𝑝𝑎.- Diameter of the tree crown.

𝐸𝑣..- Pan A Evaporation.

𝐾𝑝.- Pan A correction coefficient.

𝑄𝑒.- Discharge of the emitter.

𝐻𝑒.- Working pressure of the emitter.

𝐶𝑣𝑓.- Coefficient of manufacturing variation.

𝑇𝑜𝑑.- Daily operation time of the irrigation system.

𝑃𝐻𝑚i 𝑛.- Minimum wetting percentage.

𝑎.- Percentage of overlap between the wetting bulbs.

Table 5 Basics data for the solution of the variants

Results and analysis

Table 6 below shows the results of the agronomic design using three different procedures. The data of the field test correspond to those of a medium texture soil and an emitter flow=4L/h. The results of the hydraulic design are shown in Table 7. The net water requirements for drip irrigation were estimated using the procedure proposed by the FAO Committee of Consultants (FAO Penman - Monteith equation), considering the most critical daily evaporation at 10% probability of occurrence to take into account climatic variability (Ev10% P), the crop coefficient (Kc) and the correction coefficient due to the location of the water depth (KL). The total needs were obtained considering an application efficiency = 90% and the salinity risks. As the data for the calculation of the three variants are the same, the results are necessarily the same. Therefore the irrigation water depth should be the same as well.

Parameters

 Variants

 

 

(1)Field test

(2)Tables

(3) Alternative

Net water requirements [Nn(mm/d)].

4.29

4.29

4.29

Total water requirements [Nt(L)].

192

192

192

Depth of wet bulb [pb(m)] .

1.16

Wet bulb ratio [rb(m)].

0.85

0.547

Applied volume of water during field test [ve(L)].

Wetted surface by the dripper [AE(m2)].

2.27

0.94

Number of drippers by plant [e(u)] .

Irrigation frequency [IR(d)] .

1 (asumido)

1 (asumido)

Irrigation Timing[TR(h)]

8

 

16 (asumido)

Water depth [DR(L/p/d)].

192

192

192

Real volume of water applied by drippers [Ve(L)] .

192*****

Real wetted percentage [PHr(%)].

Table 6 Results of agronomic design

 

 Variants

 

 

Parameters       

(1)

(2)

(3)

Lateral length [Llat(m)] MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaG4wai aadYeacaWGSbGaamyyaiaadshacaGGOaGaamyBaiaacMcacaGGDbaa aa@3E2C@

200 

200 

200 

Diameter of lateral [lat MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaG4wai abgwGiglaadYgacaWGHbGaamiDaaaa@3BA8@  (mm)]

21 

27.8 

21 

Lateral discharge [QlaT(L/s)]. MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaG4wai aadgfacaWGSbGaamyyaiaadsfacaaIOaGaamitaiaai+cacaWGZbGa aGykaiaai2facaaIUaaaaa@406B@

0.34 

0.79 

0.34

Pressure loss in the lateral [H f LAT (kPa)] MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaG4wai aadIeacaWGMbqcfa4aaSbaaSqaaKqzadGaamitaiaadgeacaWGubaa leqaaKqzGeGaaiikaiaadUgacaWGqbGaamyyaiaacMcacaGGDbaaaa@42EE@

47 

54 

 47

Initial pressure in the lateral [ h 0 (kPa)] MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaG4wai aadIgajuaGdaWgaaWcbaqcLbmacaaIWaaaleqaaKqzGeGaaiikaiaa dUgacaWGqbGaamyyaiaacMcacaGGDbaaaa@406D@

184.5 

190 

184.5 

Minimum pressure in the lateral [ h MIN (kPa)] MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaG4wai aadIgajuaGdaWgaaWcbaqcLbmacaWGnbGaaeysaiaad6eaaSqabaqc LbsacaGGOaGaam4AaiaadcfacaWGHbGaaiykaiaac2faaaa@4224@

137.4 

136 

137.4 

Length of the distributor[Ldist(m)] MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaeizai aabMgacaqGZbGaaeiDaiaabkhacaqGPbGaaeOyaiaabwhacaqG0bGa ae4BaiaabkhacaaIBbGaamitaiaadsgacaWGPbGaam4Caiaadshaca GGOaGaamyBaiaacMcacaGGDbaaaa@4980@

72 

72 

72 

Initial pressure ofthe distributor [Ho(kPa)] MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaG4wai aadIeacaWGVbGaaiikaiaadUgacaWGqbGaamyyaiaacMcacaGGDbaa aa@3E05@

217 

204 

217

Minimum pressure ofthe distributor [Hmi n D (kPa)] MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaG4wai aadIeacaWGTbGaamyAaiaad6gajuaGdaWgaaWcbaqcLbmacaWGebaa leqaaKqzGeGaaiikaiaadUgacaWGqbGaamyyaiaacMcacaGGDbaaaa@432F@

159 

170 

159

Minimum pressure in the plot [Hmi n PR (kPa)] MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaG4wai aadIeacaWGTbGaamyAaiaad6gajuaGdaWgaaWcbaqcLbmacaWGqbGa amOuaaWcbeaajugibiaacIcacaWGRbGaamiuaiaadggacaGGPaGaai yxaaaa@4412@

112 

115 

112

Discharge in the valve [Qval(L/s)]. MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaG4wai aadgfacaWG2bGaaeyyaiaadYgacaaIOaGaamitaiaai+cacaWGZbGa aGykaiaai2facaaIUaaaaa@408B@

3.4 

 7.93

3.4 

Pressure in the valve [Hv(kPa)] MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaKqzGeGaaG4wai aadIeacaWG2bGaaiikaiaadUgacaWGqbGaamyyaiaacMcacaGGDbaa aa@3E0C@

217 

204 

 217  

Table 7 Results of the hydraulic design

Several results distinguish the first variant of the rest

One is the fact that by means of the field test it is possible to take into account the depth at which the wetting bulb develops. This is an important issue since it foresees the risk of dampening inappropriate depths that lead to increased losses due to deep percolation or to dislodging the wet bulb in relation to the dense root depth area of the plant and worse, can cause important effects for the plants during fertirrigation. It also influences the proper rooting of the plants, which favors the absorption of water and nutrients as well as an anchorage capable of resisting stronger winds.

The actual diameter reached by the wetting bulb at the design depth is obtained based on the results of the field test. This allows us to estimate with considerable precision the surface moistened by the emitter, which is a parameter that allows specify the number of drippers that moisten the same plant and that apply a volume that guarantees the minimum percentage of wetting in each plant. This situation is foreseen in the second variant but from tabulated values, proposed by other authors for specific conditions, which do not necessarily coincide with those of the scenarios of the projects that are carried out Table 2. The value of the bulb diameter was obtained by interpolation in this variant, for root depths and similar physical properties, for instance the surface wetted by emitter was much lower than the first variant, and therefore the number of emitters needed to meet the total water needs of the plant is greater, with a significant impact on the hydraulic design. This reasoning is confirmed due to a daily irrigation frequency is assumed and therefore the irrigation timing is less than in the first variant, so is possible to guarantee the necessary water depth with lower irrigation timing, but on account of using larger diameter of laterals (32 × 27.8), which can increase the initial cost of the installation significantly. When analyzing the deliver volume of water by emitter, according to the soil response determined in the field test, we note that in the second variant each emitter delivers a volume MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq=Jc9 vqaqpepm0xbba9pwe9Q8fs0=yqaqpepae9pg0FirpepeKkFr0xfr=x fr=xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaqcLbsacqGHij YUaaa@3836@ 50% lower than the soil assimilates in favor of the plants; besides, justifying the fact that 14 drippers must be placed instead of 6 that are needed in the first variant, also increasing the initial cost of the investment. Bearing in mind that what is interesting from the agronomic point of view of irrigation is the moisture content very close to the plant and the tensions that this generates in the soil, are a fact the inconveniences that can happen when the design is not carried out from the results of the field test. The mentioned risk becomes more evident with the third variant, since the design does not take into account the analysis of these parameters, and the number of necessary drippers to meet the total water needs of the plant is directly deduced of the water needs along the row of plants, or assumes from the nominal flow and the number of plants in the row. In this variant, the duration and frequency of irrigation are assumed at the convenience of the irrigation operation, foreseeing to deliver the necessary dose in each side of irrigation, as well as the volume of water needed for each plant depending on assuming the duration of irrigation convenient for this purpose; Contrary to what has been established in the practice of design, in which the duration of irrigation is obtained based on the total water needs, the properties of the soil and consequently the installed flow per plant. According to the results for each of the variants Table 5, no significant differences are recognized in the hydraulic design of the installation between the variants developed from the results of the field test and the alternative variant. The rigor of the procedure for the design of the facilities is in function of the appropriate communication between the designer and the investor of the work. The biggest differences are seen in the variant that uses the tabulated values proposed by other authors, this shows the need to perform a very careful analysis when assuming each design parameter.

Conclusion

  1. The diameter moistened by the emitter at the dense ruth depth of the crop is a design parameter that allows ensuring a better distribution of water and nutrients for the plants in the drip irrigation systems and must be obtained from the Field tests.
  2. The volume to be wetted by the emitter is a parameter that can increase the frequency ant timing irrigation, therefore it must be obtained experimentally or using modeling software calibrated for the project conditions.
  3. Failure to consider the results of field tests can lead to over sizing irrigation systems as well as affecting crop yields and decreasing water productivity in drip irrigation systems.

Acknowledgements

None.

Conflict of interest

The author declares that there is no conflict of interest.

References

  1. Amir I. Sprinkle and Trickle Irrigation. International Institute for Infrastructural, Hydraulic and Environmental Engineering. The Netherlands: IHE Delft; 1998.
  2. Boswel MJ. Micro Irrigation Design Manual. España Sevilla; 1990.
  3. Caupers C Junior E. Hidráulica 1. Apuntamentos das aulas teóricas. Universidad Eduardo Mondlane. Maputo Mozambique; 2007.
  4. Keller JB. Sprinkler and Trickle irrigation. New York: EEUU; 1990.
  5. Keller J, Rodrigo J. Trickle irrigation lateral design. ASAE Technical Paper. USA; 1976;(26):79.
  6. López Sánchez, JL. Fundamentals of hydraulic calculation in irrigation and drainage systems. España: Mundi editions Press; 2003.
  7. Pizarro CF.“High Frequency Localized Irrigation: Drip, Microaspersion and Exudation”. Madrid, España: Mundi editions Press; 1996.
  8. Torralba V. Localized irrigation, concepts, agronomic peculiarities and basic data. Agronomic and hydraulic design. Cuba:Ciudad Habana; 1990.